Catalog Number 111140
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Patient Involvement (2645)
Date of Event 07/12/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
It was noted that the device is not available for evaluation.If additional information is received, it will be provided in a supplemental report upon completion of the investigation.Not returned.
 
Event or Problem Description
The screw part of the slap hammer was broken before the case started.Case type: pka.
 
Additional Manufacturer Narrative
An event regarding crack/fracture involving a mako slaphammer was reported.Review of the device history records indicates devices were manufactured and accepted into final stock with no reported discrepancies.There have been no other events for the lot referenced.It was reported that the screw part of the slap hammer was broken.Material analysis of the returned device noted that the slaphammer tip had fractured.Mixed-mode and intergranular fracture morphologies were observed on the slaphammer, consistent with an overload condition.The slaphammer met the drawing requirement for hardness.The intergranular fracture morphologies are potentially due to hydrogen embrittlement.Eds showed the slaphammer was consistent with 465 ph stainless steel alloy.Based on the given information, no identifiable materials or manufacturing discrepancies were observed on the surfaces examined.The device was discovered during inspection.There was no surgical procedure associated with the reported event.This event meets the definition of preventive maintenance; no further investigation is required at this time.If additional information becomes available to indicate further evaluation is warranted, this record will be reopened.
 
Event or Problem Description
The screw part of the slap hammer was broken before the case started.Case type: pka.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FEMORAL TRIAL SLAPHAMMER
Common Device Name
PROSTHESIS, KNEE PATELLOFEMOROTIBIAL, PARTIAL, SEMI-CONSTRAINED, CEMENTED, POLYM
Manufacturer (Section D)
MAKO SURGICAL CORP.
2555 davie road
fort lauderdale FL 33317
MDR Report Key7764875
Report Number3005985723-2018-00472
Device Sequence Number11077358
Product Code NPJ
UDI-Device Identifier00848486002732
UDI-Public00848486002732
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
K090763
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 11/20/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/30/2020
Device Catalogue Number111140
Device Lot Number06111015
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/20/2018
Initial Date Received by Manufacturer 07/12/2018
Supplement Date Received by Manufacturer10/25/2018
Initial Report FDA Received Date08/08/2018
Supplement Report FDA Received Date11/20/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-