Device malfunctioned intra-operatively and was not implanted / explanted.The screw head was removed, while the screw shaft was left in the patient.Complainant part is expected to be returned for manufacturer review/investigation, but has yet to be received.Without a lot number the device history records review could not be completed.The investigation could not be completed; no conclusion could be drawn, as no product was received.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Manufacturing location: monument; manufacturing date: may 16, 2018; expiration date: april 30, 2027; part: 04.005.526s, 5.0mm ti locking screw w/t25 stardrive 36mm f/im nail ¿ sterile; lot: h635828 (sterile); lot quantity 126.Work order traveler met all inspection acceptance criteria.Inspection sheet, whirl threads, vibe, flute / final inspection met all inspection acceptance criteria.Packaging label log (pll) was reviewed and was found to be conforming.Packaging bom for this lot was reviewed and found to be conforming with no deviations to normal packaging identified.Component(s) reviewed: part: 04.005.526.999, 5.0mm ti screw blank 36mm 05.0 nail lock screw w/sd25; lot: h570501; lot quantity: 486 work order traveler met all inspection acceptance criteria.23020, tialnbci4.98, lot: 7032665; lot quantity: 2,887 lbs.Product certification received from dynamet was reviewed and determined to be conforming.Product traveler met all inspection acceptance criteria.Raw material receiving/putaway checklist met all inspection acceptance criteria.This lot met all dimensional, visual, sterilization and packaging criteria at the time of release with no issues documented during the manufacture that would contribute to this complaint condition.Us customer quality (cq) investigation workflow: broken visual inspection: visual inspection performed at cq observed that the screw head broke from the shaft at the intersection of the screw head and shaft.The break was complete and uniform across the intersection, with only minute traces of the shaft.Only the screw head portion of the screw was returned.Based on visual inspection, the received condition agreed with the complaint condition - the complaint condition was confirmed.Dimensional inspection: dimensional inspection of the broken screw could not be conducted due to post-manufacturing deformation.Document/specification review: device history record(s) showed that there were no issues during the manufacture of this product including the materials and its properties, which would contribute to this complaint condition.A relevant drawing for the returned device was reviewed during the investigation (the drawing at the time of manufacture is current): tabulated drawing for the 5.0mm locking screw.During the investigation, no product design or manufacturing issues were observed that may have contributed to the complaint condition.During the investigation, no product design or manufacturing issues or discrepancies were observed that may have contributed to the complaint condition.Conclusion: the complaint condition of a broken screw was confirmed.There were no issues during the manufacture of this product that would contribute to this complaint condition.During the investigation, no product design issues or discrepancies were observed that may have contributed to the complaint condition.While no definitive root cause could be determined, it is possible that the screw experienced abnormal forces during insertion when encountering interference from another device or tissue.This situation may arise due to a variety of reasons, including but not limited to misalignment of the insertion handle and/or aiming arm, improper preparation of the insertion site and/or insertion location, or high bone density.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|