Catalog Number 21346
Medical Device Problem Code Incorrect, Inadequate or Imprecise Result or Readings (1535)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Event or Problem Description
A customer in (b)(6) contacted biomérieux to report the occurrence of a misidentification of campylobacter species as neisseria cinerea in association with the vitek® 2 neisseria-haemophilus (nh) identification (id) test kit.The customer did not indicate if repeat or confirmatory testing was performed.There is no indication or report from the laboratory or physician that the discrepant result led to any adverse event related to the patient's state of health.Biomérieux requested strain submittal from the customer.A biomérieux internal investigation will be initiated.
 
Additional Manufacturer Narrative
A customer in (b)(6) had contacted biomérieux to report the occurrence of a misidentification of campylobacter species as neisseria cinerea in association with the vitek® 2 neisseria-haemophilus (nh) identification (id) test kit.An internal biomérieux investigation was performed.The customer's strain and raw data were not available.The customer had incubated the isolate at 42c for 48 hours.The nh culture requirements table states the age of culture range is 18-24 hours for campylobacter isolates.Strains tested outside of the recommended culture requirements may give atypical results.The strain was identified by the customer lab as campylobacter species by gram stain morphology and positive campylobacter agglutination testing.One lab report was received.The lab report submitted had an 88% probability of neisseria cinerea with five atypical negative reactions ( odc, pvate, dmlt, lglm, dxyl) for an identification of campylobacter species.An increased number of atypical negative results can indicate a strain with decreased viability, user set up error or an atypical strain.Without the strain or raw data it is not possible to further evaluate the cause of the mis-identification.The vitek 2 nh id card, lot #2450433103, met final qc release criteria.The lot passed qc performance testing.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VITEK® 2 NEISSERIA-HAEMOPHILUS (NH) IDENTIFICATION (ID) TEST KIT
Common Device Name
VITEK® 2 NH ID CARD
Manufacturer (Section D)
BIOMERIEUX INC.
595 anglum road
saint louis MO 63042
MDR Report Key7774033
Report Number1950204-2018-00286
Device Sequence Number1966959
Product Code JST
UDI-Device Identifier03573026144357
UDI-Public03573026144357
Combination Product (Y/N)N
Initial Reporter CountryMK
PMA/510(K) Number
CL. I EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,health professional,u
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/22/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/02/2018
Device Catalogue Number21346
Device Lot Number2450433103
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/13/2018
Supplement Date Received by Manufacturer09/25/2018
Initial Report FDA Received Date08/10/2018
Supplement Report FDA Received Date10/22/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-