• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SMITHS MEDICAL ASD, INC. PORTEX BIVONA NEONATAL AND PEDIATRIC TT (TIGHT-TO-SHAFT) TRACHEOSTOMY TUBES; JOH

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SMITHS MEDICAL ASD, INC. PORTEX BIVONA NEONATAL AND PEDIATRIC TT (TIGHT-TO-SHAFT) TRACHEOSTOMY TUBES; JOH Back to Search Results
Catalog Number 67SP0306
Medical Device Problem Code Defective Component (2292)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Event or Problem Description
Information was received that the bivona tracheostomy tube would not inflate as they prepared for use.No reported adverse effects.
 
Additional Manufacturer Narrative
One used sample was returned for evaluation.During testing, the operator noted the device cuff would not fully inflate.After the operator manually manipulated the cuff as per device instructions, the device cuff fully inflated.The device instructions include the direction: "attach a syringe to the pilot balloon and slowly inflate the cuff with 5ml of sterile water.If the cuff does not inflate completely, squeeze the pilot balloon wile gently manipulating the cuff from the shaft.If the cuff still does not inflate, use a new tube, save the old tube and call smiths medical customer service.Deflate the cuff prior to intubations." the inflated cuff was measured and was found to meet with specifications for cuff symmetry.The manufacturing facility performed a review of the manufacturing process.The review showed that assembly process was being performed as per procedures.This review included the following procedures: basic assembly, manual cleaning and inspection.The manufacturing facility also performed an in-process visual inspection of 32 products that were in the assembly area: this inspection showed no issues with the products being assembled.The root cause could not be established; the returned device was found to meet with specifications.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PORTEX BIVONA NEONATAL AND PEDIATRIC TT (TIGHT-TO-SHAFT) TRACHEOSTOMY TUBES
Common Device Name
JOH
Manufacturer (Section D)
SMITHS MEDICAL ASD, INC.
6000 nathan lane north
minneapolis MN 55442
MDR Report Key7774578
Report Number3012307300-2018-03073
Device Sequence Number19180435
Product Code JOH
UDI-Device Identifier15021312000696
UDI-Public15021312000696
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K914088
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source user facility
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 09/30/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device No Information
Device Expiration Date06/02/2022
Device Catalogue Number67SP0306
Device Lot Number3437793
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/18/2018
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/13/2018
Supplement Date Received by Manufacturer07/13/2018
Initial Report FDA Received Date08/10/2018
Supplement Report FDA Received Date09/30/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-