OLYMPUS WINTER & IBE GMBH JAWS "HIQ+", 5 X 330 MM, NEEDLE HOLDER, CURVED; NEEDLE HOLDERS (HANDLES, JAWS INSERTS)
|
Back to Search Results |
|
| Model Number |
WA64710A |
| Medical Device Problem Codes |
Break (1069); Fracture (1260); Material Fragmentation (1261); Mechanical Problem (1384)
|
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
08/06/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The suspect medical device has not yet been returned to olympus for evaluation/investigation.Therefore, the exact cause of the user's experience and the reported phenomenon could not be determined and is being judged as unknown.However, if the suspect medical device is returned for evaluation/investigation or additional significant information becomes available, this report will be updated.
|
| |
|
Event or Problem Description
|
|
Olympus was informed that during a therapeutic appendectomy procedure, the jaws of the needle holder broke and a fragment fell inside the patient's body cavity.However, no fragment remained inside the patient since it was reportedly retrieved.The intended procedure was successfully completed using a similar device and there was no report about an adverse event or patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
The suspect medical device was not returned to the manufacturer for evaluation/investigation but to olympus medical systems corporation (omsc), japan (returned to omsc on 2018-08-09).The investigation confirmed that the stationary jaw of the grasping forceps had broken off.In the last months, an increased occurrence of complaints regarding this phenomenon was noticed and, thus, a capa was initiated (reference # capa-150p-050).In addition, a sales stop was implemented as part of this capa.In the course of the capa investigation, the following two contributing factors were identified as the root cause: undersized cross-section due to construction specifications and minor deviations that may occur during the manual production processes, and metallurgical embrittlement caused by the influences of the heat treatment during the manual soldering process.Thus, the root cause of the breakage was identified as a design weakness that may lead to the reported phenomenon if both factors occur at the same time in a worst case scenario.Suitable countermeasures as well as risk and trending evaluations are performed within the capa process.The risk to patient, user, and/or third party associated with this phenomenon was evaluated as acceptable.This case will be closed from olympus side since all further activities will be covered by the capa.
|
| |
|