| Model Number |
M00565010 |
| Medical Device Problem Codes |
Difficult or Delayed Positioning (1157); Positioning Problem (3009)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
07/23/2018
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).According to the complainant, the stent remains implanted and is not available for return.If any further relevant information is received, a supplement mdr will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported to boston scientific corporation on (b)(6) 2018 that a wallflex duodenal stent has been implanted to treat a 3/4 cm malignant stricture in the duodenum during a stent placement procedure performed on (b)(6) 2018.Reportedly, the patient's anatomy was not tortuous and was not dilated prior to stent placement.According to the complainant, during procedure, the stent was attempted to be deployed, however, there was difficulty fully deploying the stent.When the outer sheath was manually pulled and the stent was deployed but was not in the target location.Reportedly, the physician left the stent in place and a larger duodenal stent (9 cm) was implanted to complete the procedure.The patient's condition at the conclusion of the procedure was reported to be fine.
|
| |
|
Additional Manufacturer Narrative
|
|
According to the complainant, the stent remains implanted and is not available for return.If any further relevant information is received, a supplement mdr will be filed.(model #), and (premarket/510(k)#) have been corrected.The stent remains implanted and will not be available for return.
|
| |
|
Event or Problem Description
|
|
It was reported to boston scientific corporation on (b)(6) 2018 that a wallflex duodenal stent has been implanted to treat a 3/4 cm malignant stricture in the duodenum during a stent placement procedure performed on (b)(6) 2018.Reportedly, the patient's anatomy was not tortuous and was not dilated prior to stent placement.According to the complainant, during procedure, the stent was attempted to be deployed, however, there was difficulty fully deploying the stent.When the outer sheath was manually pulled and the stent was deployed but was not in the target location.Reportedly, the physician left the stent in place and a larger duodenal stent (9 cm) was implanted to complete the procedure.The patient's condition at the conclusion of the procedure was reported to be fine.
|
| |
|