MAUDE Adverse Event Report: ABBOTT MOLECULAR, INC. ABBOTT M2000SP INSTRUMENT; CLINICAL SAMPLE CONCENTRATOR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT MOLECULAR, INC. ABBOTT M2000SP INSTRUMENT; CLINICAL SAMPLE CONCENTRATOR Back to Search Results
Catalog Number 09K14-02
Medical Device Problem Code Human-Device Interface Problem (2949)
Health Effect - Clinical Code Abrasion (1689)
Date of Event 08/16/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
An elevated complaint investigation will be performed.H4 will be provided with the follow up report.
 
Event or Problem Description
The abbott m2000 system is intended for use in performing nucleic acid testing in clinical laboratories.It is comprised of the abbott m2000sp and the abbott m2000rt instruments.The abbott m2000sp is an automated system for performing sample preparation for nucleic acid testing.The abbott m2000rt is an automated system for performing fluorescence-based pcr to provide quantitative and qualitative detection of nucleic acid sequences.The customer states that their master mix addition run for hiv-1 routine ended normally.The customer tried to lift the amplification reagent packs from the assay reagent holder on the output deck of the m2000sp instrument to discard them, but the packs didn't come out easily, so the customer applied more force to do so.At one time while lifting, the customer couldn´t take the amplification pack, and her hand crashed with the robotic manipulator arm, resulting in tearing of the glove and a cut on the knuckles with blood.After that, the customer tried to clean the blood from the arm, but she cut her index finger (while using gloves), reporting the edge of the arm is sharp.The customer washed her injuries for 30 minutes with water and soap.Customer stated she went to the physician after the accident.She was tested for hiv-1, hcv and hbv; results were negative.She was vaccinated against tetanus and is under antiretroviral treatment for 1 month.No patient was involved, injury was sustained by an abbott m2000sp instrument user.This incident is being reported to fda because the incident occurred in colombia using the m2000sp instrument, list number 09k14-02, which is also approved for use in the united states.
 
Additional Manufacturer Narrative
Investigation into this complaint included an existing data review, a quality data review, a complaint history review and a product/system/instrument evaluation.Investigation is summarized as follows: existing data review: review of the m2000sp operations manual list 9k20-009, 200681-109 march 2016, identified that personal injury described in this complaint were the direct result of customer use outside of instrument instructions.The operator did not remove the amplification reagent packs from the instrument as directed in the operations manual, which instructs the operator to unload the amplification reagent packs after first removing the assay reagent holder from the instrument.In addition, the customer attempted to clean the roma gripper finger resulting in another injury.Review of applicable labeling verified that there are no instructions to clean or maintain the roma gripper fingers.Quality data review: no related nonconformances or capa records were found related to sharp edges related to the roma gripper fingers of the m2000sp instrument.Complaint history review showed that, over the last two years, no other related complaints were identified.Additionally, no related nonconformances or capa records were found related to the lot of the plastic reagent pack commodity used during the complaint run.Complaint history review showed that no other complaints were identified related to reagent pack fitment issues.Service history review: revealed m2000sp sn10474 was installed at the complaint customer site in bogota, colombia in april 2012.No additional service tickets were identified related to personal injuries or any reports of sharp edges on this instrument.Retain sample evaluation: replacement spare parts are not retained for the m2000sp e-series instrument as it is a serialized device.Retains of the amplification pack used at the time of the reported injuries were not evaluated as all other elements of this investigation do not indicate any systemic product deficiency with the plastic reagent pack used to manufacture this part.Return sample evaluation: the roma gripper fingers associated with the ticket under investigation were returned to abbott molecular for evaluation.Measurements on both ends of the section of the gripper arms reported to cause injury verified that the part remained within specification tolerances.Testing per ul1439 only indented the test tape, meaning no sharp edge per iec 61010-1 was present.Returns of the relevant reagent pack were not available.Engineering evaluation - safety assessment per the applicable sections of iec 61010-1 safety standard, section 7 contains general requirements for sharp edges: all easily-touched parts of the equipment shall be smooth and rounded so as not to cause injury during normal use.Review of engineering drawings for the roma gripper arms identified that by design sharp edges are removed, all burs are to be removed, and all external corners are rounded.In-house testing on five m2000sp instruments demonstrated the roma gripper fingers did not cut the outer sensing tape, meaning no injury would result from contact with a finger.Based on the results of investigation, no product deficiency has been identified.
 
Event or Problem Description
The abbott m2000 system is intended for use in performing nucleic acid testing in clinical laboratories.It is comprised of the abbott m2000sp and the abbott m2000rt instruments.The abbott m2000sp is an automated system for performing sample preparation for nucleic acid testing.The abbott m2000rt is an automated system for performing fluorescence-based pcr to provide quantitative and qualitative detection of nucleic acid sequences.The customer states that their master mix addition run for hiv-1 routine ended normally.The customer tried to lift the amplification reagent packs from the assay reagent holder on the output deck of the m2000sp instrument to discard them, but the packs didn't come out easily, so the customer applied more force to do so.At one time while lifting, the customer couldn´t take the amplification pack, and her hand crashed with the robotic manipulator arm (roma), resulting in tearing of the glove and a cut on the knuckles with blood.After that, the customer tried to clean the blood from the arm, but she cut her index finger (while using gloves), reporting the edge of the arm is sharp.The customer washed her injuries for 30 minutes with water and soap.Customer stated she went to the physician after the accident.She was tested for hiv-1, hcv and hbv; results were negative.She was vaccinated against tetanus and is under antiretroviral treatment for 1 month.Clarification received (b)(6), 2018 that user medical treatment included lamivudina zidovudina and lopinavir + ritonavir.No patient was involved, injury was sustained by an abbott m2000sp instrument user.This incident is being reported to fda because the incident occurred in colombia using the m2000sp instrument, list number 09k14-02, which is also approved for use in the united states.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ABBOTT M2000SP INSTRUMENT
Common Device Name
CLINICAL SAMPLE CONCENTRATOR
Manufacturer (Section D)
ABBOTT MOLECULAR, INC.
1300 e. touhy ave.
des plaines IL 60018 3315
MDR Report Key7825190
Report Number3005248192-2018-00010
Device Sequence Number19132170
Product Code JJH
UDI-Device Identifier00884999031753
UDI-Public00884999031753
Combination Product (Y/N)N
Initial Reporter CountryCO
PMA/510(K) Number
K092705
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 09/25/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Operator of Device No Information
Device Catalogue Number09K14-02
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/18/2018
Initial Date Received by Manufacturer 08/23/2018
Supplement Date Received by Manufacturer08/31/2018
Initial Report FDA Received Date08/28/2018
Supplement Report FDA Received Date09/25/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age38 YR
Patient Weight53
-
-