Model Number M0068403940
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 08/08/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).The device has been received for analysis; however the evaluation has not been completed.Therefore, the cause of the reported malfunction has not been determined.Upon completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.
 
Event or Problem Description
It was reported to boston scientific corporation on (b)(6) 2018 that a flexiva 1000 laser fiber was used during a lithotripsy procedure in the bladder performed on (b)(6) 2018.Reportedly, the laser unit used was a lumenis 100 watt console.According to the complainant, during the procedure, the physician noted that the fiber tip detached after two minutes of use.Reportedly, no fiber fragments fell inside the patient.The procedure was completed with a non-bsc laser fiber.There were no serious injury nor adverse patient effects reported as a result of this event.
 
Event or Problem Description
It was reported to boston scientific corporation on (b)(6) 2018 that a flexiva 1000 laser fiber was used during a lithotripsy procedure in the bladder performed on (b)(6) 2018.Reportedly, the laser unit used was a lumenis 100 watt console.According to the complainant, during the procedure, the physician noted that the fiber tip detached after two minutes of use.Reportedly, no fiber fragments fell inside the patient.The procedure was completed with a non-bsc laser fiber.There were no serious injury nor adverse patient effects reported as a result of this event.
 
Additional Manufacturer Narrative
(b)(4).Visual examination revealed that there was approximately 0.5 mm of exposed glass fiber tip remaining.Additional examination under magnification revealed that the pattern on the tip face was consistent with a fracture indicating that the tip or portion of the tip broke off.The condition of the returned device confirmed the event.Therefore, a review and analysis of all available information indicated that the root cause is adverse event related to procedure.A complaint with a cause of adverse event related to procedure indicates that the adverse event occurred during the procedure and the device had no influence on event.A review of the device history record (dhr) was performed and no deviations were found.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FLEXIVA
Common Device Name
POWERED LASER SURGICAL INSTRUMENT
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
MDR Report Key7842880
Report Number3005099803-2018-60239
Device Sequence Number1981513
Product Code GEX
UDI-Device Identifier08714729808121
UDI-Public08714729808121
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K100078
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 11/28/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/08/2021
Device Model NumberM0068403940
Device Catalogue Number69145
Device Lot Number0000006151
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/15/2018
Initial Date Received by Manufacturer 08/08/2018
Supplement Date Received by Manufacturer11/06/2018
Initial Report FDA Received Date09/04/2018
Supplement Report FDA Received Date11/28/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-