| Model Number |
36721 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Bradycardia (1751); Cardiac Arrest (1762)
|
| Date of Event |
08/14/2018
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported the patient experienced bradycardia and a brief period of asystole.Preliminary ultrasonography showed a 1.3x1.6 cm hypoechouc nodule in hepatic segment vi.The patient was prepared in supine position under aseptic draping and combined general-local anesthesia for a radiofrequency ablation (rfa) procedure.A 4.0 cm leveen rfa needle was navigated into the nodule ultrasonographic guidance.Ablation was performed and during first position of ablation (about 10 mins at about 170 watts) with 4.0 diameter of expansion, the patient developed bradycardia (heart rate from 80 bpm to 30 bpm) and then asystole (duration about 2-3 seconds) and spontaneous recovery.The events of bradycardia occurred about 5-6 cycles.0.3 mg of atropine was given by anesthesiologist.Then the session was stopped.Total ablative time was about 13 minutes.Re-ablation was done at 130 watts and the patient developed bradycardia again.The session was then terminated.Mild hyperechoic change was seen and the tract was ablated.The patient's condition was stable.
|
| |
|
Event or Problem Description
|
|
It was reported the patient experienced bradycardia and a brief period of asystole.Preliminary ultrasonography showed a 1.3x1.6 cm hypoechouc nodule in hepatic segment vi.The patient was prepared in supine position under aseptic draping and combined gereral-local anesthesia for a radiofrequency ablation (rfa) procedure.A 4.0 cm leveen rfa needle was navigated into the nodule ultrasonographic guidance.Ablation was performed and during first position of ablation(about 10 mins at about 170 watts) with 4.0 diameter of expansion, the patient developed bradycardia (heart rate from 80 bpm to 30 bpm) and then asystole (duration about 2-3 seconds) and spontaneous recovery.The events of bradycardia occurred about 5-6 cycles.0.3 mg of atropine was given by anesthesiologist.Then the session was stopped.Total ablative time was about 13 minutes.Re-ablation was done at 130 watts and the patient developed bradycardia again.The session was then terminated.Mild hyperechoic change was seen and the tract was ablated.The patient's condition was stable.It was further reported that the physician believes the cause of the bradycardia/asystole was parasympathetic stimulation.The patients status is currently (b)(6) - restricted in physically strenuous activity but ambulatory and able to carry out work of a light or sedentary nature.
|
| |
|
Search Alerts/Recalls
|