Catalog Number S02020-75
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 07/18/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.The device has not been returned, at this time, to the manufacturer for evaluation.A lot history review (lhr) of asbus0094 showed no other similar product complaint(s) from this lot number.Device has not yet been returned for evaluation.
 
Event or Problem Description
It was reported that during puncture the miniloc presented leakage.No patient harm was reported.
 
Additional Manufacturer Narrative
The following were reviewed as part of this investigation: patient severity, frequency analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of a leak during use is unconfirmed since the problem could not be reproduced.One 20 ga x 0.75 in miniloc infusion set was returned for investigation.The safety mechanism was activated prior to return.The sample was flushed with water using a 12 ml syringe and was found to be patent to infusion.The safety mechanism was deactivated and a non-complainant port septum was used to occlude the needle.The sample was pressurized and no leaks were observed.Since no leaks were observed during flushing and pressurization, the complaint is unconfirmed.A lot history review (lhr) of asbus0094 showed no other similar product complaint(s) from this lot number.
 
Event or Problem Description
It was reported that during puncture the miniloc presented leakage.No patient harm was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MINILOC SAFETY INFUSION SET 20G X 0.75IN
Common Device Name
SET, ADMINISTRATION, INTRAVASCULAR
Manufacturer (Section D)
BARD ACCESS SYSTEMS
605 n. 5600 w.
salt lake city UT 84116
MDR Report Key7853052
Report Number3006260740-2018-02372
Device Sequence Number19317902
Product Code FPA
UDI-Device Identifier00801741048784
UDI-Public(01)00801741048784
Combination Product (Y/N)N
PMA/510(K) Number
K050600
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 11/21/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberS02020-75
Device Lot NumberASBUS0094
Was Device Available for Evaluation? No
Event Location Hospital
Initial Date Received by Manufacturer Not provided
Supplement Date Received by Manufacturer11/12/2018
Initial Report FDA Received Date09/06/2018
Supplement Report FDA Received Date11/21/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-