Patient information was not provided for reporting.Date of event is unknown.Device is an instrument and is not implanted / explanted.The device was received, and the product evaluation is in progress.No conclusion can be drawn.Additionally, device history records review has been requested.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Device history record (dhr) review: part: 03.008.009; lot: 7742361; manufacturing site: hägendorf; release to warehouse date: 02 march 2012.The device history record shows this lot of 5 pieces was processed through the normal manufacturing and inspection operations with no rework or nonconformities noted.This lot met all dimensional, visual and functional criteria at the time of release with no issues documented during the manufacturing process.Review of the device history record showed that there were no issues during the manufacture of this product which would contribute to this complaint condition.Investigation summary: we have forwarded the received part to the responsible manufacturing site for further evaluation with the following results: selected flow: 2.Device interaction/functional.2.1 visual inspection: the shipped back 03.008.009 aim-arm f/expert han f/03.008.007, lot 7742361, is in a used condition.No special or heavy used look.2.2 functional test: the function test was executed accorded the then valid inspection sheet and passed it.Following function gauges have been used: gauge article number 50171481 with gauge number 7377-h; gauge article number 50163412 with gauge number 7380-h; gauge article number 50161303 with gauge number 9026-h.2.3 drawing/specification review: relevant design drawings were reviewed.The manufactured and current revisions of the drawings were reviewed, and no relevant design changes were identified.2.5 material or hardness review: it can be confirmed that the correct components have been used when zielbüg-aufsatz f/expert han z/03.008.00 was assembled.4.2 conclusion: during manufacturing investigation, all relevant and significant characteristics were checked and the article passed all functional tests.In accordance to the test results no misalignment or any other production error has been found.We only can assume that during the operation an application error may have taken place.To prevent such problems, it is necessary to operate according to the technique guide.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|