Model Number B-2240
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Codes Muscle Spasm(s) (1966); Pain (1994)
Date of Event 02/01/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Taper ii.Device evaluation summary: a visual examination was performed on the returned, lap-band with access port ii and taper type ii.The band ring and shell were noted to be separated near the band buckle.The port tubing was noted to be separated approximately 2.5 inches past the ss connector.Needle marks were noted on the port septum.Scratches were noted on the port housing and port holes.A port leak test was performed, and no leakage was noted.An air leak test was performed, and leakage was noted from one opening, where the band ring and shell were noted to be separated.A fill inspection test was performed, and no blockage was noted when colored di water was passed through the port septum and tubing.Under microscopic analysis, both ends of the separated band ring and shell were noted to have striated edges, consistent with damage from a surgical end cut to remove the device.Material degradation was noted to be covering approximately 20% of the band shell.Both ends of the port tubing, separated approximately 2.7 inches past the ss connector, were noted to have a striated origination point, consistent with damage from a surgical tool.Needle marks were noted on the port septum.Non-penetrating nicks/marks were noted on the port housing, the port holes, and the port base.Review of the device labeling notes the following: precautions: it is the responsibility of the surgeon to advise the patient of the known risks and complications associated with the surgical procedure and implant.Care must be taken during band adjustment to avoid puncturing the tubing that connects the access port and band, as this will cause leakage and deflation of the inflatable section.Failure to create a stable, smooth path for the access port tubing, without sharp turns or bends, can result in tubing breaks and leakage.In order to avoid incorrect placement, the port should be placed lateral to the trocar opening.A pocket must be created for the port so that it is placed far enough from the trocar path to avoid abrupt kinking of the tubing.The tubing path should point in the direction of the access port connector so that the tubing will form a straight line with a gentle arching transition into the abdomen.When adjusting band volume, the needle must be inserted perpendicular to the access port septum.Failure to do so may cause damage to the port and result in leaks.When adjusting band volume after the septum is punctured, do not tilt or rock the needle, as this may cause fluid leakage or damage to the septum.Adverse events: it is important to discuss all possible complications and adverse events with your patient.Complications which may result from the use of this product include the risks associated with the medications and methods utilized in the surgical procedure, the risks associated with any surgical procedure and the patient's degree of intolerance to any foreign object implanted in the body.Unplanned deflation of the band may occur due to leakage from the band, the port or the connecting tubing.Other adverse events considered related to the lap-band® system that occurred in fewer than 1% of subjects included: esophagitis, gastritis, hiatal hernia, pancreatitis, abdominal pain, hernia, incisional infection, infection, redundant skin, dehydration, gi perforation, diarrhea, abnormal stools, constipation, flatulence, dyspepsia, eructation, cardiospasm, hematemesis, asthenia, fever, chest pain, incision pain, contact dermatitis, abnormal healing, edema, paresthesia, dysmenorrhea, hypochromic anemia, band leak, cholecystitis, esophageal dysmotility, esophageal ulcer, esophagitis, port displacement, port site pain, spleen injury and wound infection.Other adverse events considered related to the lap-band® system that occurred in fewer than 2% of study patients included: diarrhea (n=2), gastric pouch dilatation (n=2), gastritis (n=2), esophageal dilatation (n=2), syncope (n=2), seroma (n=2).Other events reported to occur in only one patient per event included; abdominal discomfort, alopecia, anemia, arthralgia, decrease blood folate, flatulence, gastrointestinal motility disorder, bronchitis, chills, implant site infection, implant site irritation, implant site hemorrhage, night sweats, hypotrichosis, headache, nail infection, pyrexia, skin irritation, esophageal obstruction, esophageal spasm, postoperative infection, urinary tract infection, muscle spasms, depression, back pain, and hypertension.Warnings: patients should be advised that the lap-band ap® system is a long-term implant.Explant (removal) and replacement surgery may be indicated at any time.Medical management of adverse reactions may include explantation.Revision surgery for explantation and replacement may also be indicated to achieve patient satisfaction.
 
Event or Problem Description
Reported as: a patient with the lap-band system was reported to have had the adjustable gastric band placed in approx.11 years ago.Since then the patient has been complaining of having pain in the pelvic area for the past five months and has stomach spasms that are random and not associated with anything.A laparoscopic replacement procedure was performed 5 months ago of the entire adjustable gastric band system, through the incision of cicatrix.The lap-band catheter was disconnected from the end of catheter in pelvis.Unable to visualize pelvic structures due to excess omentum.The cicatrix incised along lesser curve.Lap-band was extracted in its entirety while slipping the new band through the old tract.Aside the adjustments done after placement of the gastric band in 2007, patient had no other complaint except from the pelvic pain for 5 months before this admission.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LAP-BAND AP STANDARD W/ ACCESS PORT I
Common Device Name
ADJUSTABLE GASTRIC BAND
Manufacturer (Section D)
APOLLO ENDOSURGERY, INC.
1120 s capitol of texas hwy
bldg 1, ste 300
austin TX 78746
MDR Report Key7873097
Report Number3006722112-2018-00229
Device Sequence Number13949673
Product Code LTI
UDI-Device Identifier10811955020183
UDI-Public10811955020183
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
P000008
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2007
Device Explanted Year2018
Reporter Type Manufacturer
Report Source other,user facility
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 08/17/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/19/2009
Device Model NumberB-2240
Device Catalogue NumberB-2240
Device Lot Number1489807
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/27/2018
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 08/17/2018
Initial Report FDA Received Date09/13/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age48 YR
Patient Weight118
-
-