Catalog Number 436020D
Medical Device Problem Codes Peeled/Delaminated (1454); Naturally Worn (2988)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 08/20/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Visual and optical examination of the centerpiece revealed a few of the gear teeth of the centerpiece have been broken off.Functional inspection of the sliding end cap confirmed it is jammed and will no longer function correctly.It appears the biologics that were used during the procedure caused the centerpiece to jam and break the teeth of the sliding end cap.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Procedure: corpectomy pre-operative diagnosis: trauma burst fracture implanted level: l3 it was reported that on (b)(6) 2018, intra-op, stratosphere cage stripped.The product came in contact with the patient.It appeared that some metal may have peeled off.No fragment of the implant or instrument remaining in the patient.No patient complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
T2 STRATOSPHERE¿ EXPANDABLE CORPECTOMY SYSTEM
Common Device Name
SPINAL VERTEBRAL BODY REPLACEMENT DEVICE
Manufacturer (Section D)
MEDTRONIC SOFAMOR DANEK USA, INC
4340 swinea rd
memphis TN 38118
MDR Report Key7882318
Report Number1030489-2018-01249
Device Sequence Number1940252
Product Code MQP
UDI-Device Identifier00643169663190
UDI-Public00643169663190
Combination Product (Y/N)N
Initial Reporter StateCO
Initial Reporter CountryUS
PMA/510(K) Number
K173125
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/17/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number436020D
Device Lot NumberCA17J058
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/10/2018
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/20/2018
Initial Report FDA Received Date09/17/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age30 YR
-
-