Model Number SMCYLCST
Medical Device Problem Code Inflation Problem (1310)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 08/30/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter, during a laparoscopic, endoscopic component separation, when the balloon was placed to create the space between the externus and internus aponeurosis, the balloon did not inflate.Another device was opened and used to complete the case.There was no patient injury.
 
Additional Manufacturer Narrative
Evaluation summary: post market vigilance (pmv) led an evaluation of one device.The visual inspection noted: that the dissector balloon and insufflation bulb, lock collar, trocar balloon and obturator appeared intact.The inflation syringe was not received.The circular seal for the dissector balloon was cut.A functional evaluation found that pmv performed functional testing; using a test syringe the trocar balloon was inflated, no leaks detected.The hole for the dissector balloon was covered, the balloon was inflated, no leaks detected.Records from each manufacturing lot are thoroughly reviewed to ensure that products are released meeting all quality release specifications at the time of manufacture.Replication of the cut in the circular seal may occur when mishandled during clinical application.The root cause of the observed damage was misuse of the product which caused or contributed to the reported condition.No further actions have been deemed necessary at this time.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SPACEMAKER
Common Device Name
LAPAROSCOPE, GENERAL & PLASTIC SURGERY
Manufacturer (Section D)
US SURGICAL PUERTO RICO
201 sabanetas industrial park
ponce PR 00716 4401
MDR Report Key7893446
Report Number2647580-2018-04615
Device Sequence Number16731094
Product Code GCJ
UDI-Device Identifier20884521545332
UDI-Public20884521545332
Combination Product (Y/N)N
Initial Reporter CountryAU
PMA/510(K) Number
K151356
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 11/27/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/30/2019
Device Model NumberSMCYLCST
Device Catalogue NumberSMCYLCST
Device Lot NumberP7F1178X
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/04/2018
Initial Date Received by Manufacturer 08/30/2018
Supplement Date Received by Manufacturer11/03/2018
Initial Report FDA Received Date09/20/2018
Supplement Report FDA Received Date11/27/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-