Catalog Number TSFB-35-145
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 06/22/2015
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).This mdr is being filed after the associated complaint was reviewed under remediation protocol cap (b)(4), complaint/mdr retrospective review and remediation and reassessed as reportable.Additional complaint investigation and record remediation was not performed.
 
Event or Problem Description
The complainant reported that the bentson straight fixed core wire guide would not advance in the sheath.The wire coating was reportedly stripped from the wire guide, so another device was used to complete the lower extremity arteriogram.It was further noted that there was coil elongation near the distal end of the device, and separation of the distal weld connection from the safety wire and coil.This product issue occurred prior to patient contact, and it did not result in any reported impact on the procedure.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BENTSON STRAIGHT FIXED CORE WIRE GUIDE
Common Device Name
DQX WIRE, GUIDE, CATHETER
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key7897916
Report Number1820334-2018-02893
Device Sequence Number1473226
Product Code DQX
UDI-Device Identifier00827002006911
UDI-Public(01)00827002006911(17)200504(10)5783066
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,user f
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 09/21/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/04/2020
Device Catalogue NumberTSFB-35-145
Device Lot Number5783066
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/25/2015
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/13/2018
Initial Report FDA Received Date09/21/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-