BECTON DICKINSON MEDICAL SYSTEMS BD LUER-LOK¿ SYRINGE WITH PRECISIONGLIDE¿ NEEDLE; SYRINGE WITH NEEDLE Back to Search Results
Catalog Number 309578
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 09/04/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Date of event: unknown.A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported with the use of the bd luer-lok¿ syringe with precisionglide¿ needle there was an issue with scale marking error.There was no report of injury or medical intervention.
 
Additional Manufacturer Narrative
Investigation summary: ten sealed 3ml packaged syringes with needle were received and confirmed to be from batch #8155886 (p/n 309578).The samples were visually evaluated.All ten syringes have more than 50% of the print missing.The entire scale is affected with the majority of the lower scale missing.The missing print observed is rejectable per product specification.A device history record review showed no rejected inspections or quality issues during the production of the provided lot number that could have contributed to the reported defect.Potential root cause for the print defect is associated with the marking process.No corrective actions are necessary based on the defective rate identified.Complaints received for this device and reported condition will continue to be tracked and trended.Information will be captured on trend reports and monitored monthly.Our business team regularly reviews the collected data for identification of emerging trends.
 
Event or Problem Description
It was reported with the use of the bd luer-lok¿ syringe with precisionglide¿ needle there was an issue with scale marking error.There was no report of injury or medical intervention.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD LUER-LOK¿ SYRINGE WITH PRECISIONGLIDE¿ NEEDLE
Common Device Name
SYRINGE WITH NEEDLE
Manufacturer (Section D)
BECTON DICKINSON MEDICAL SYSTEMS
route 7 and grace way
canaan CT 06018
MDR Report Key7903477
Report Number1213809-2018-00624
Device Sequence Number19238716
Product Code FMF
UDI-Device Identifier30382903095781
UDI-Public30382903095781
Combination Product (Y/N)N
Initial Reporter StateAZ
Initial Reporter CountryUS
PMA/510(K) Number
K980987
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source other,user facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/05/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date05/31/2023
Device Catalogue Number309578
Device Lot Number8155886
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/12/2018
Initial Date Received by Manufacturer 09/04/2018
Supplement Date Received by Manufacturer09/04/2018
Initial Report FDA Received Date09/24/2018
Supplement Report FDA Received Date10/10/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-