| Model Number |
840 |
| Medical Device Problem Code |
No Flow (2991)
|
| Health Effect - Clinical Codes |
No Consequences Or Impact To Patient (2199); No Code Available (3191)
|
| Date of Event |
09/03/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).If information is provided in the future, a supplemental report will be issued.
|
| |
|
Event or Problem Description
|
|
It was reported that while in use on a patient, the 840 ventilator stopped ventilation and the systems were locked out.There was no injury to the patient as a result of the event.
|
| |
|
Additional Manufacturer Narrative
|
|
The entire ventilator was reported to be expected to return for further evaluation but has not been received by medtronic at this time.Should the ventilator be returned to the manufacturing site, an additional evaluation will be performed and a supplemental report will be submitted.
|
| |
|
Event or Problem Description
|
|
The patient was placed on an alternate ventilator and there was no harm to the patient as a result of the event.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information received regarding evaluation of the device.Device evaluation updated: the ventilator was evaluated and an inoperable error code was found.Self-testing was completed successfully.However, the entire ventilator was reported to be expected to return for further evaluation.The unit has not been returned to the manufacturing site for further evaluation at this time.Should the ventilator be returned to the manufacturing site, an additional evaluation will be performed and a supplemental report will be submitted.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Additional Manufacturer Narrative
|
|
Device evaluation summary: the 840 ventilator was received by medtronic and an investigation was performed.The unit was found to have scratches and marks which would be normal for the unit's service life.The graphical user interface (gui) housing plastic handle was also found to be damaged.During review of the ventilator logs, the reported error code was confirmed on the noted event date.The unit was found to pass calibrations and self-testing without any errors.The unit ran in normal ventilation mode with no errors or unexpected alarms.The inspiratory module and oxygen proportional solenoid (psol) were removed from the ventilator for further inspection.No anomalies were observed upon an external visual inspection.The inspiratory module and oxygen psol were reinstalled onto the ventilator and the unit underwent testing.The ventilator once again ran under normal ventilator mode with no errors or unexpected alarms.The reported issue could not be duplicated.The cause was suspected to be over pressure on the oxygen supply line to the ventilator.The inspiratory module was removed once again for further analysis.The inspiratory module was observed under a microscope and bronze fragments were found dislodged on the oxygen impact bronze filter.Excessive high pressure on the oxygen (o2) pipe into the ventilator could cause bronze filter fragments to be deposited inside the o2 oxygen inlet filter that could have caused that filter to temporarily rupture under high pressure, and then generate the reported ventilator inoperative condition.The excessive high pressure at the oxygen channel regulator input could cause the output to exceed the limits.If information is provided in the future, a supplemental report will be issued.
|
| |
|