• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: STRYKER SPINE-US XIA LP POLYAXIAL SCREW 6.5 X 55MM; THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM22

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER SPINE-US XIA LP POLYAXIAL SCREW 6.5 X 55MM; THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM22 Back to Search Results
Catalog Number 03821655
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 08/15/2018
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that after insertion of the right side nail with blocker, screw pull out was confirmed in image examination.The screw has been removed and replaced.When the left side nail and screw were placed, it also pulled out during compression; the screw was removed and replaced by another, which had the head locked.The doctor removed the screw and chose not to put another.It was further reported that one of the screws did pull out of the head and after pullout verified, it was noticed that the ring on the inside of the screw had broken without large loose fragments.The surgical incision was washed.There are no reports of adverse consequences to the patient.
 
Additional Manufacturer Narrative
Method: visual inspection, product history review, complaint history review, nc/capa history review, labeling review, risk assessment.Result: the customer reported event of was confirmed via visual inspection.The screw was returned in 2 pieces as the tulip was disengaged from the screw shank.The bottom of the tulip was deformed heavily on one side, indicating that the tulip head was over angulated in one direction and suboptimal rod placement.Additionally, the damage on the screw shows that the tulip was over angulated until it eventually disengaged.Rod divot on the screw shank head indicates that the rod was not fully perpendicular with the screw when final tightening occurred and was at an angle inside the tulip.Manufacturing records were reviewed for the corresponding lot and no relevant issues were identified.The surgical technique calls for the rod to be perpendicular to the screw when being seated into the rod.Conclusion: the most likely root cause is the position of the rod caused additional torque to be applied to the screw which eventually caused the tulip to disengage.
 
Event or Problem Description
It was reported that after insertion of the right side nail with blocker, screw pull out was confirmed in image examination.The screw has been removed and replaced.When the left side nail and screw were placed, it also pulled out during compression; the screw was removed and replaced by another, which had the head locked.The doctor removed the screw and chose not to put another.It was further reported that one of the screws did pull out of the head and after pullout verified, it was noticed that the ring on the inside of the screw had broken without large loose fragments.The surgical incision was washed.There are no reports of adverse consequences to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
XIA LP POLYAXIAL SCREW 6.5 X 55MM
Common Device Name
THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM22
Manufacturer (Section D)
STRYKER SPINE-US
2 pearl court
allendale NJ 07401
MDR Report Key7910827
Report Number3005525032-2018-00059
Device Sequence Number11159465
Product Code NKB
UDI-Device Identifier04546540149268
UDI-Public04546540149268
Combination Product (Y/N)N
Initial Reporter StatePR
Initial Reporter CountryBR
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source distributor
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 12/20/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device No Information
Device Catalogue Number03821655
Device Lot NumberB23407
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/12/2018
Initial Date Received by Manufacturer 08/27/2018
Supplement Date Received by Manufacturer11/28/2018
Initial Report FDA Received Date09/26/2018
Supplement Report FDA Received Date12/20/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-