Model Number 4132005
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 08/16/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.The device has not been returned, at this time, to the manufacturer for evaluation.A lot history review (lhr) of rezd0413 showed no other similar product complaint(s) from this lot number.
 
Event or Problem Description
It was reported rupture of the catheter with no apparent cause.It was stated the standard protocol of handling was followed.No other information was provided.
 
Additional Manufacturer Narrative
The following were reviewed as part of this investigation: patient severity, trend analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of a broken per-q-cath catheter was confirmed and the cause appeared to be use-related.The product returned for evaluation was one 2fr s/l per-q-cath catheter.Usage residues were observed.The catheter was received in two segments which shared a complete break within the molded joint region.Curved shape memory was observed in the vicinity of the break.Microscopic inspection of the break site revealed a coarsely granular break surface.The catheter exhibited an elliptical cross-section at the break site.Tactile inspection of the sample revealed tensile weakness, necking and discoloration in the vicinity of the break.The break characteristics, tensile weakness, necking and discoloration were consistent with damage caused by tensile (pulling) stress.The location of the damage suggested that catheter securement, maintenance and access/de-access technique may have contributed.
 
Event or Problem Description
It was reported rupture of the catheter with no apparent cause.It was stated the standard protocol of handling was followed.No other information was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PER-Q-CATH PLUS PICC 2F BASIC TRAY (SINGLE-LUMEN) (30 CM)
Common Device Name
CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
Manufacturer (Section D)
BARD ACCESS SYSTEMS
605 n. 5600 w.
salt lake city UT 84116
MDR Report Key7915743
Report Number3006260740-2018-02608
Device Sequence Number1539665
Product Code LJS
UDI-Device Identifier00801741074820
UDI-Public(01)00801741074820
Combination Product (Y/N)N
Initial Reporter CountryBR
PMA/510(K) Number
K954104
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,other
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 02/12/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number4132005
Device Catalogue Number4132005
Device Lot NumberREZD0413
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/27/2018
Event Location Hospital
Initial Date Received by Manufacturer Not provided
Supplement Date Received by Manufacturer02/01/2019
Initial Report FDA Received Date09/27/2018
Supplement Report FDA Received Date02/12/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-