Catalog Number 406091
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 09/07/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The pma/510(k)#: enforcement discretion.Medical device expiration date: unknown.Device manufacture date: unknown.A device evaluation and/or device history review is anticipated, but is not complete.Upon completion, a supplemental report will be filed.
 
Event or Problem Description
It was reported that bd¿ epidural tray single shot, double deck tuohy 18 gauge 3-1/2 inch exhibited packaging failure and breach in sterility.No serious injury or medical intervention was reported.
 
Additional Manufacturer Narrative
A sample was provided for evaluation.Evaluation of the sample confirmed the internal wrap was torn within the field of the wrap therefore failure mode is verified.The complaint sample evaluation was not able to identify a potential source for the tear.The probable root cause could not be identified.A review of the device history record shows that all inspection results passed per the dhr process and no anomalies were noticed during production.All anesthesia tray packaging are all 100% inspected throughout the process.Based on the evidence of the punctured wrap, which is highly visible, the defect would have triggered a rejection by the manufacturing personnel immediately.It is possible the tray caused the wrap to tear handling or during transportation post manufacturing.Consequently, the investigation was not able to identify a probable root cause.
 
Event or Problem Description
It was reported that bd epidural tray single shot, double deck tuohy 18 gauge 3-1/2 inch exhibited packaging failure and breach in sterility.No serious injury or medical intervention was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD¿ EPIDURAL TRAY SINGLE SHOT, DOUBLE DECK TUOHY 18 GAUGE 3-1/2 INCH
Common Device Name
EPIDURAL TRAY
Manufacturer (Section D)
CAREFUSION, INC
400 east foster rd
mannford OK 74044
MDR Report Key7926339
Report Number1625685-2018-00041
Device Sequence Number770400
Product Code CAZ
UDI-Device Identifier00382904060916
UDI-Public00382904060916
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
PMA/510(K) Number
SEE H.10
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source other,user facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/30/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Other
Device Catalogue Number406091
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/14/2018
Initial Date Received by Manufacturer 09/10/2018
Supplement Date Received by Manufacturer09/10/2018
Initial Report FDA Received Date10/02/2018
Supplement Report FDA Received Date10/31/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-