• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SMITH & NEPHEW, INC. REF XLPE 28 20 DEG 54-56 F; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SMITH & NEPHEW, INC. REF XLPE 28 20 DEG 54-56 F; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED Back to Search Results
Catalog Number 71333325
Medical Device Problem Code Mechanical Problem (1384)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 09/11/2018
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the reflection microstable locking mechanism liner failed to lock inside with the reflection cup during total hip replacement procedure.The surgeon found it difficult once dislocation was done with the original polar prosthesis.The surgeon could not fix the liner since it was not locking properly.Almost one hour twenty minutes was spent on the table, implants were removed from the patient.
 
Additional Manufacturer Narrative
The associated complaint devices were returned and evaluated.A visual inspection of the returned liner indicated damage to the liner lip, with damage to the porous coating of the shell, and the screws showed some damage to the threads and hex feature.A dimensional evaluation of the liner indicated surface damage noted on the face of the liner.Damage was also noted to the porous coating of the shell and to the id of the shell, especially around the gage point of the screw holes.For the shell, minor deviations were noted on the spherical radius of the id and the profiles of the holes at gage point, which were consistent with the observed damage from attempted use.Minor deviations were also noted on the profile of the splines.For the liner, the profile of splines at gage point measured oversize on cmm, and the profile of locking detail also failed overlay inspection.All other checks measured in specification for both parts.Functionally, it was possible to lock the liner into the shell with considerable force.A dimensional evaluation of the screws could not verify failure mode as the returned screws function as intended per inspection methods.All relevant dimensions are within drawing tolerances.A review of the manufacturing records did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.A review of complaint history on the listed parts revealed prior complaints for the listed batches.Based on this investigation, the need for corrective action is not indicated.No further investigation is warranted for this complaint; however we will continue to monitor for future complaints and investigate further as necessary.Should additional information be received, the complaint will be reopened.We consider this investigation closed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
REF XLPE 28 20 DEG 54-56 F
Common Device Name
PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks road
memphis TN 38116
MDR Report Key7931883
Report Number1020279-2018-02043
Device Sequence Number1798147
Product Code LPH
UDI-Device Identifier03596010455628
UDI-Public03596010455628
Combination Product (Y/N)N
Initial Reporter CountryIN
PMA/510(K) Number
K002747
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 05/09/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number71333325
Device Lot Number18CM21301
Initial Date Received by Manufacturer 09/11/2018
Supplement Date Received by Manufacturer09/11/2018
09/11/2018
Initial Report FDA Received Date10/03/2018
Supplement Report FDA Received Date03/19/2019
05/09/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
75100464 / B1807880
Outcome Attributed to Adverse Event Other; Required Intervention;
-
-