Catalog Number 7577545
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 09/19/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Neither the device nor films of applicable imaging studies were returned to the manufacturer for evaluation.Therefore, we are unable to determine the definitive cause of the reported event.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
It was reported that intra-op, a screw broke.It was removed and replaced.No patient complications were reported as a result of this event.
 
Additional Manufacturer Narrative
Product analysis: visual inspection confirmed the bone screw disassembled from the head.The ring and crown were still assembled in the head.A portion of the retaining ring has been bent and sheared off.The bent/sheared section is sticking out of the bottom of the head with the remaining portion of the ring still seated in the groove of the head.Microscopic inspection confirmed witness marks inside the crown of the screw.The bone screw head diameter found to be within print specification.The above observations are consistent with overload as the mechanism of failure.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CD HORIZON SPINAL SYSTEM
Common Device Name
APPLIANCE, FIXATION, SPINAL INTERLAMINAL
Manufacturer (Section D)
WARSAW ORTHOPEDICS
2500 silveus crossing
warsaw,in TN 46582
MDR Report Key7946172
Report Number1030489-2018-01334
Device Sequence Number856484
Product Code KWP
UDI-Device Identifier00885074032047
UDI-Public00885074032047
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K032265
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2018
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 05/16/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number7577545
Device Lot Number0103485W
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/22/2019
Initial Date Received by Manufacturer 09/19/2018
Supplement Date Received by Manufacturer04/22/2019
Initial Report FDA Received Date10/09/2018
Supplement Report FDA Received Date05/16/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age39 YR
-
-