• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: WRIGHTS LANE SYNTHES USA PRODUCTS LLC 3.5MM LCP RECONSTRUCTION PLATE 8 HOLES/112MM; APPLIANCE,FIXATION,NAIL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

WRIGHTS LANE SYNTHES USA PRODUCTS LLC 3.5MM LCP RECONSTRUCTION PLATE 8 HOLES/112MM; APPLIANCE,FIXATION,NAIL Back to Search Results
Model Number 245.081
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Code Available (3191)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Device is not expected to be returned for manufacturer review/investigation.(b)(4).Device evaluation/investigation could not be completed; no conclusion could be drawn as product was not returned to manufacturer.Additionally, device history records review has been requested.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that on (b)(6) 2018 a patient underwent a revision surgery of the right scapula for failed fixation and loss of anatomic reduction, due to patient compliance.There was no report of malfunction with any of the devices.A locking compression plate 6 holes, lcp reconstruction plate 8 holes, two (2) 3.5mm unknown locking screws, nine (9) 3.5mm unknown cortex screws and one (1) 2.7mm unknown cortex screw were removed.Bone loss required fibular strut allograft placement and infuse bone morphogenetic proteins (bmp).During revision, patient was implanted with new fixation.Original implant date is unknown, less than one year prior to the revision surgery.The plates were intentionally bent or contoured during initial implantation.Surgical delay is unknown.Procedure was successfully completed, and patient outcome was as planned.This report is for one (1) locking compression plate, 8 holes.This is report 2 of 5 for (b)(4).
 
Event or Problem Description
It was further reported that during revision, patient was implanted with following fixation: a lcp superior clavicle plates, a variable angle lcp lateral anterior clavicle plates, two (2) 2.7 mm locking screws 8mm, a 2.7 mm locking screws 10mm, two (2) 2.7 mm locking screws 12mm, 2.7 mm variable locking screws 10mm, 2.7 mm variable locking screws 22mm, 3.5 mm locking screws 16mm, two (2) 3.5 mm locking screws 18mm, 3.5 mm locking screws 22mm, 3.5mm cortex screws 18mm, and 3.5mm cortex screws 28mm.
 
Additional Manufacturer Narrative
If the information is unknown, not available or does not apply, the section/field of the form is left blank.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Dhr review was attempted.Part/lot combination are unknown at synthes gmbh, no dhr review possible.Customer quality conducted a review of the provided medical images.No product was returned; the investigation was performed based upon a review of the received medical images.Upon review of the medical images, the complaint condition is unable to be confirmed.The image shows the intact plate with slight contouring on both sides of hole 4 from the left end of the plate.The cause for the complaint condition is not able to be determined.Based on the information available, it has been determined that no corrective and preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
3.5MM LCP RECONSTRUCTION PLATE 8 HOLES/112MM
Common Device Name
APPLIANCE,FIXATION,NAIL
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key7964865
Report Number2939274-2018-54364
Device Sequence Number19190847
Product Code KTT
UDI-Device Identifier10886982169624
UDI-Public(01)10886982169624
Combination Product (Y/N)N
Initial Reporter StateUT
Initial Reporter CountryUS
PMA/510(K) Number
K000684
Number of Events Summarized1
Summary Report (Y/N)N
Device Explanted Year2018
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 09/28/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number245.081
Device Catalogue Number245.081
Device Lot Number36806
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 09/28/2018
Supplement Date Received by Manufacturer10/15/2018
11/16/2018
Initial Report FDA Received Date10/15/2018
Supplement Report FDA Received Date10/16/2018
11/19/2018
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age63 YR
-
-