Reporter is synthes sales representative.The device was received, and the product evaluation is in progress.No conclusion can be drawn.Additionally, device history records review has been requested.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthese is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthese has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthese or its employees that the report constitutes an admission that the device, depuy synthese, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.Part: 03.900.022; lot: 2667561; manufacturing site: bettlach; release to warehouse date: (b)(6) 2011 the device history record shows this lot was processed through the normal manufacturing and inspection operations with no rework or nonconformities noted.This lot met all dimensional, visual and packaging criteria at the time of release with no issues documented during the manufacturing process.The material was reviewed, and the hardness value was confirmed to meet the specification with no non-conformance noted.Review of the device history record showed that there were no issues during the manufacture of this product which would contribute to this complaint condition.Investigation site: cq zuchwil; selected flow: 5.Broken visual inspection: two blades of the cruciform screwdriver are broken off and were not sent back for evaluation.At the intact blades are deformations in counter-clockwise direction visible.Dimensional inspection: checked dimensions with caliper per drawing: thickness intact blade 1 specification 0.5mm +0.02/-0.04 / measured: 0.48mm = pass thickness intact blade 2 specification 0.5mm +0.02/-0.04 / measured: 0.49mm = pass drawing/specification review: the review of the handling technique has shown that this screwdriver is part of the screw extraction set.As stated in the technique, complications may arise in the case of implant removal e.G.By damaged screws.Material or hardness review: the review of the manufacturing documents has shown that with 1.4028 stainless steel the correct material was used and that the hardness was within the specification 48 +4/0 hrc.Summary: the complaint condition is confirmed, but no manufacturing related issue could be detected.There was no information provided on how or when the screwdriver broke, therefore the exact cause of this occurrence cannot be defined.The visible deformations in counter-clockwise direction let us assume that a mechanical overload during the extraction of a possibly blocked or damaged screw did lead to the breakage of the device.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed as no product related issue could be detected.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|