If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Patient id, (b)(6).Complainant part is not expected to be returned for manufacturer review/investigation.(b)(4).Device history lot: please note, this dhr review is for sterilization procedure only: part no.: 04.008.266s; lot no.: 7414554; manufacturing location: (b)(4); supplier: (b)(4); release to warehouse date: 28.Aug.2013; expiry date: 01.Aug.2023.Non-sterile 04.008.266 / 7414554 was manufactured in us, (b)(4).Manufacturing location: (b)(4).Manufacturing date: 10-jul-2013.Part number: 04.008.266, 12mm ti hindfoot arthrodesis cann nail ¿ ex 180mm/left.Lot number: 7414554 (non-sterile).Lot quantity: (b)(4).Note: this lot number was produced as a non-sterile item.Work order traveler met all inspection acceptance criteria apart from the noted inspection sheet, in-process acceptance sheet, met all inspection acceptance criteria.Inspection sheet met all inspection acceptance criteria.Inspection sheet, final inspection, met all inspection acceptance criteria.Packaging label log was reviewed and determined to be conforming.This lot met all dimensional, visual and packaging criteria at the time of release with no issues documented during the manufacture that would contribute to this complaint condition.Investigation summary: the investigation could not be completed; no conclusion could be drawn, as no product was received.Product was not returned.Based on the information available, it has been determined that no corrective and preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.
|
|
It was reported that on (b)(6) 2018 a patient underwent hardware removal due to infection.The devices removed were one (1) hindfoot arthrodesis cannulated nail, one (1) titanium spiral blade, one (1) 6.0mm titanium locking screw, one (1) titanium end cap, one (1) titanium locking screw 50mm, and two (2) titanium locking screws 30mm.The original implant for the devices is (b)(6) 2018.The patient and procedure outcome is unknown.Concomitant devices reported: vivigen formable biologic tissue matrix (product# bl-1600.002, lot unknown, quantity 1).This report is for (1) 12mm ti hindfoot arthrodesis cann nail-ex 180mm/lt-sterile.This complaint involves seven (7) devices.This report is 1 of 7 for (b)(4).
|