Model Number PCB00
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Code Available (3191)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Date of event: unknown, an exact date was not provided.But it was mentioned that the symptoms were first observed between 1 and 4 weeks post-op; therefore the best estimate is (b)(6) 2018.If explanted, give date: not applicable as to date the lens remains implanted and therefore not explanted.(b)(6).(b)(4).Device evaluation: the intraocular lens (iol) was not returned at the manufacturing site as to date it remains implanted.Therefore product testing could not be performed and the customer's reported complaint could not be verified.Manufacturing records review: the manufacturing records for the intraocular lens were reviewed.The product was manufactured and released according to specification.Historical data analysis: a search revealed that no additional complaints for this order number have been received.Labeling review: the directions for use (dfu) were reviewed.The directions for use (dfu) adequately provides instructions and precautions along with warnings for the proper use and handling of the device.As a result of the investigation there is no indication of a product quality deficiency and the reported issue could not be verified.All pertinent information available to johnson and johnson surgical vision, inc.Has been submitted.
 
Event or Problem Description
It was reported that after the implantation of the intraocular lens (model pcb00 +29.0 diopter), the patient experienced severe positive dysphopsia.Reportedly, the symptoms were first observed between 1 and 4 weeks post-op and they currently interfere with the patient''s ability to drive.It was also noted that the patient had a limited yag (yttrium aluminium garnet) 2 months post surgery which did not resolve the symptoms.No other medical or surgical intervention was performed or planned at present, though the customer is considering a silicone piggyback lens if thought useful.Patient vision is 6/4 unaided.No further information was provided.
 
Additional Manufacturer Narrative
This correction mdr is being submitted to address inaccurate information on the xml version of the previous submission caused by a software glitch in the transmission process.The internal non-conformance numbers for this software issue are (b)(4) and capa-(b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TECNIS ITEC PRELOADED 1-PIECE IOL
Common Device Name
MONOFOCAL IOLS
Manufacturer (Section D)
JOHNSON AND JOHNSON SURGICAL VISION, INC.
santa ana CA
MDR Report Key8011658
Report Number2648035-2018-01401
Device Sequence Number13819185
Product Code HQL
UDI-Device Identifier05050474558441
UDI-Public(01)05050474558441(17)200915
Combination Product (Y/N)Y
Initial Reporter CountryUK
PMA/510(K) Number
P980040
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 11/04/2020
Report Date (Section F) 01/01/2005
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date09/15/2020
Device Model NumberPCB00
Device Catalogue NumberPCB0000290
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Date Report to Manufacturer01/10/2005
Initial Date Received by Manufacturer 09/28/2018
Supplement Date Received by Manufacturer10/25/2020
Initial Report FDA Received Date10/28/2018
Supplement Report FDA Received Date11/04/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Date Report Sent to FDA01/01/2005
-
-