Model Number G48028
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 09/07/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
510 (k) number: k163468.Cook ireland ltd (manufacturer) is submitting this report on behalf of cook medical incorporated (cmi)(importer).Exemption number: e2016031.Information pertaining to section g.1 as follows: importer site contact and address: (b)(4) cook medical incorporated (cmi) 1025 acuff road p.O box 4195 bloomington indiana 47402-4195.Importer site establishment registration number: 3005580113.Investigation is still pending.A follow up mdr will be submitted to include the investigation conclusions.
 
Event or Problem Description
As reported to customer relations: "after traversing stricture with wire guide stent was placed over wireguide and placed down scope, after stent was exiting scope it felt difficult to push, the sent was then in position but under fluoroscopic image the tip of stent appeared to be approx 5cm away from end of stent, nurse began squeezing trigger to begin to deploy, with great difficulty - then she felt and we heard a snap- unable to recapture or deploy - stent was removed from scope and it did not deploy - we used another evolution colonic stent of same size to complete procedure.".
 
Additional Manufacturer Narrative
510 (k) number: k163468.Cook ireland ltd (manufacturer) is submitting this report on behalf of cook medical incorporated (cmi)(importer).Exemption number: e2016031.Importer site contact and address: (b)(4) cook medical incorporated (cmi) 1025 acuff road p.O box 4195 bloomington indiana 47402-4195.Importer site establishment registration number: 3005580113.Lab evaluation: the device involved in the complaint was evaluated in the laboratory on 03 october 2018.Outer flexor was broken at shuttle cap.Documents review including ifu review: prior to distribution all evo-25-30-8-c devices are subject to visual inspection and functional checks to ensure device integrity.There inspections and functional checks are outlined in internal procedures in place at cirl upon review of complaints, this failure mode has not occurred previously with the lot number c1328257.Based on the information available to date, there is no evidence to suggest that there are any manufacturing issues associated with the lot number c1328257.The instructions for use ifu0052-10 which accompanies this device instructs the user to "visually inspect with particular attention to kinks, bends and breaks.If an abnormality is detected that would prohibit proper working condition, do not use".There is no evidence to suggest that the customer did not follow the instructions for use (ifu0052-10).Root cause review: the failure of ¿outer flexor was broken at shuttle cap" was observed in the laboratory.A possible root cause of ¿delamination of the ptfe liner of the outer sheath¿ was identified in the laboratory.It may be noted that a project was completed by product development to further investigate stent deployment issues of this nature in an effort to eliminate future occurrences.Summary: customer complaint confirmed as failure was verified in laboratory according to the information reported, the patient did not experience any adverse effects due to this occurrence.Complaints of this nature will continue to be monitored for potential emerging trends.
 
Event or Problem Description
The device was evaluated on the 03-oct-18 confirming the "outer flexor was broken at shuttle cap." this fie is being reported on the fda mdr reportable reporting precedence for this device family for the issue of ¿flexor kinked/ stretched/ broke/ compressed¿.As reported to customer relations: "after traversing stricture with wire guide stent was placed over wireguide and placed down scope, after stent was exiting scope it felt difficult to push, the sent was then in position but under fluroscopic image the tip of stent appeared to be approx 5cm away from end of stent, nurse began squeezing trigger to begin to deploy, with great difficulty - then she felt and we heard a snap- unable to recapture or deploy - stent was removed from scope and it did not deploy - we used another evolution colonic stent of same size to complete procedure.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVOLUTION® COLONIC CONTROLLED-RELEASE STENT - UNCOVERED
Common Device Name
MQR STENT, COLONIC METALLIC EXPANDABLE
Manufacturer (Section D)
COOK IRELAND LTD
o halloran road
limerick
MDR Report Key8024920
Report Number3001845648-2018-00511
Device Sequence Number1382442
Product Code MQR
UDI-Device Identifier10827002480282
UDI-Public(01)10827002480282(17)190221(10)C1328257
Combination Product (Y/N)N
Initial Reporter StateCT
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/31/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/21/2019
Device Model NumberG48028
Device Catalogue NumberEVO-25-30-8-C
Device Lot NumberC1328257
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/02/2018
Was the Report Sent to FDA? No
Distributor Facility Aware Date10/31/2018
Event Location Hospital
Initial Date Received by Manufacturer 09/12/2018
Supplement Date Received by Manufacturer09/12/2018
Initial Report FDA Received Date10/31/2018
Supplement Report FDA Received Date11/29/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-