MENTOR TEXAS MENTOR CPX 4 BREAST TISSUE EXPANDER WITH SUTURE TABS; EXPANDER, SKIN, INFLATABLE Back to Search Results
Catalog Number 3549316
Medical Device Problem Code Material Rupture (1546)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 09/28/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The mentor failure analysis lab has received the device for evaluation.The analysis has begun, but is not complete at this time.When the investigational analysis has been completed, a supplemental report will be submitted.The device history record (dhr) was reviewed, and no anomalies were found related to this complaint.In addition, the dhr review verifies that the device was manufactured in accordance with documented specification and procedures.(b)(4).
 
Event or Problem Description
It was reported that a mentor cpx 4 breast tissue expander with suture tabs 750cc had a hole when the box was opened.The hole was discovered pre-operation so there was no patient contact.
 
Additional Manufacturer Narrative
It was reported that a mentor cpx 4 breast tissue expander with suture tabs 750cc had a hole when the box was opened.The hole was discovered pre-operation so there was no patient contact.The device was returned to mentor without fluid inside.No foreign material was observed within the device or on the shell surface.The mentor product analysis lab discovered a rent measuring approximately 2.4 cm on the posterior aspect.Microscopic examination of the edges of the rent revealed parallel striations.No other anomalies were discovered.The complaint was confirmed since a rupture was found in the device.Microscopic examination revealed parallel striations.This type of striations is more conclusive to sharp instrument damage rather than shell failure due to wear.Breast implants are not considered lifetime devices and deflation is a known complication associated with these devices and is referenced in our product insert data sheet.(b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MENTOR CPX 4 BREAST TISSUE EXPANDER WITH SUTURE TABS
Common Device Name
EXPANDER, SKIN, INFLATABLE
Manufacturer (Section D)
MENTOR TEXAS
3041 skyway circle north
irving TX 75038
MDR Report Key8028892
Report Number1645337-2018-06562
Device Sequence Number1093553
Product Code LCJ
UDI-Device Identifier00081317006824
UDI-Public00081317006824
Combination Product (Y/N)N
Initial Reporter StateID
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 10/04/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/23/2022
Device Catalogue Number3549316
Device Lot Number7565808
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/11/2018
Initial Date Received by Manufacturer 10/04/2018
Supplement Date Received by Manufacturer11/05/2018
Initial Report FDA Received Date11/01/2018
Supplement Report FDA Received Date11/26/2018
Patient Sequence Number1
-
-