Reporter is a synthes employee.The device was received, the investigation is in progress, no conclusion could be drawn at the time of filing this report.A device history record review has been requested.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Device history lot part number:03.312.811, lot number: h536949, release to warehouse: 12-jan-2018, manufactuirng location:brandywine.A review of the device history record evaluated the sub component 03.321.810.5 part in lot (h366859).The product disposition will be to release lot h366959.The parts are conforming as per supplier data for lot h366859 that was attached.Therefor these two non-conformance are not related to the complaint description.Review of the raw material dhrs showed that there was no issues during the manufacturing of the product that would contribute to this complaint action.No ncrs to scrap were generated for raw material.Investigation summary visual inspection visual inspection of the returned strut assembly performed at cq revealed that the threaded rod component was broken into two pieces at the toroid groove feature.The fracture occurred at approximately the center of the groove and was approximately perpendicular across the rod¿s longitudinal axis.There were no material abnormalities; a fracture point was noted slightly off-center, that indicated the device fractured under off-axis torsional stress.The two pieces were retained within the (1) clevis for the threaded rod component and (2) strut tube.The received condition agreed with the complaint description.The complaint was confirmed.Dimensional inspection a relevant dimensional inspection was not able to be performed due to the received condition of the device.Review of the device history record(s) showed that the lot went through the required steps during the inspection at the time of manufacturing and showed no issues concerning the material or material conditioning.Document/specification review no product design issues or discrepancies were observed.Conclusion: the complaint was confirmed with investigation.No product design issues or manufacturing discrepancies that would contribute to the reported complaint condition were identified during this investigation.As the conditions at the time of the event were unknown, a definitive root cause could not be determined.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|