|
SMITH & NEPHEW, INC. LGN PRESSFIT STEM 22MM X 160MM; PRSTHSS, KNEE, PTLLFMRTBIAL, SM-CNSTRND, CMNTD, POLYMER/METAL/POLYMER
|
Back to Search Results |
|
| Catalog Number |
71424055 |
| Medical Device Problem Code |
Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Code |
No Code Available (3191)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that patient had occasional clicking and popping while walking.Doctor suggested a constrained knee revision and synovectomy since implants appear to be well fixed and aligned but there are some subtle radiolucencies around cementless stems.A constrained polyethylene available was requested by the doctor for the revision surgery and potentially revision implants, although unlikely to be needed.Information about revision surgery hasn't been received.
|
| |
|
Additional Manufacturer Narrative
|
|
The associated legion pressfit stems and genesis ii ps insert were not returned for evaluation.Therefore a product analysis could not be performed.However, device details were provided.The manufacturing records and complaint history review was conducted.The review of the manufacturing records for the insert and the femoral component did not reveal any deviation from the standard manufacturing processes.The review of the complaint history for the listed parts revealed no prior complaints for the listed failure mode with the same batch number.At this time, we have no reason to suspect that the products failed to meet any product specifications at the time of manufacture.A relationship, if any, between the devices and the reported incident or adverse event could not be corroborated.A clinical evaluation noted that the reported pre-revision events are most likely related to the early report of mild tilting of the smaller tibial tray, lateral patellar tracking coupled with the early onset of symptoms suggesting residual instability post primary implantation and concerns of the varus alignment.Delayed revision potentially contributed to the severity of the patient¿s worsening symptoms.The patient impact was the persistent anterior knee pain and other reported progressive symptoms in addition to the 1st revision surgery and an expected 2nd revision with a brief post-operative rehabilitative phase.Due to the recurrence of ¿symptomatic scar tissue formation ¿ with a flexion instability post-1st revision, future similar concerns cannot be definitively excluded.No further medical assessment can be rendered at this time.Without the return of the actual products involved, our investigation of this report is inconclusive.No further investigation is warranted for this complaint; however smith and nephew will continue to monitor for future complaints and investigate as necessary.Should the devices or additional information be received, the complaint will be reopened.
|
| |
|
Search Alerts/Recalls
|
|
|