Medical Device Problem Code Pumping Problem (3016)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The pump has not been returned to animas for evaluation.If the device is returned, an evaluation shall be completed and a supplemental report will be filed.No conclusions can be made at this time.
 
Event or Problem Description
On (b)(6) 2018, the reporter contacted animas, alleging a history/settings (history/settings issue) issue; the reporter stated that the pump is not providing an alarm when the patient's blood glucose is low.There is no indication the alleged product issue caused or contributed to an adverse event.This issue is being reported as an issue with the pump not performing as intended with regards to the history or the settings may result in over or under delivery.
 
Additional Manufacturer Narrative
Device evaluation: the device has been returned and evaluated by product analysis on 17-dec-2018 with the following findings: a review of the black box and continuous glucose monitoring (cgm) showed a call service 208 cgm glucose above user limit warnings.The review of the user settings showed the cgm high limit alert was enabled and set to 80 mg/dl.The battery compartment and returned battery cap was undamaged and able to fit.The test transmitter was paired with the pump correctly.The blood glucose calibration of 120 mg/dl was accepted on both attempts within 2 hours.A test call service 208 warning was simulated with 100 mg/dl as a threshold.The pump gave the appropriate call service 208 warning with auditory and vibratory alarms.The alleged ¿absence of low blood glucose¿ issue was unable to be duplicated during testing.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ANIMAS VIBE
Common Device Name
INSULIN INFUSION PUMP
Manufacturer (Section D)
ANIMAS LLC
965 chesterbrook blvd
wayne PA 19087
MDR Report Key8045446
Report Number2531779-2018-19220
Device Sequence Number13859315
Product Code OYC
UDI-Device Identifier10840406100082
UDI-Public10840406100082
Combination Product (Y/N)Y
Initial Reporter StateMN
Initial Reporter CountryUS
PMA/510(K) Number
P130007
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source consumer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 10/26/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/29/2018
Was the Report Sent to FDA? Yes
Device Age37 MO
Initial Date Received by Manufacturer 10/26/2018
Supplement Date Received by Manufacturer10/26/2018
Initial Report FDA Received Date11/07/2018
Supplement Report FDA Received Date12/21/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age71 YR
-
-