STRYKER NEUROVASCULAR CORK TRANSFORM COMPLIANT 5MM X 15MM; CATHETER, INTRAVASCULAR OCCLUDING, TEMPORARY
|
Back to Search Results |
|
| Catalog Number |
M003SRC05150 |
| Medical Device Problem Code |
Deflation Problem (1149)
|
| Health Effect - Clinical Code |
Thrombus (2101)
|
| Date of Event |
10/16/2018
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that during the procedure, the balloon catheter was unable to deflate, due to thrombus formation inside the balloon lumen.The physician was able to get rid of the thrombus by manipulating the guidewire and the balloon was able to deflate.The balloon was continued to be used; however, similar issue occurred.The balloon was removed from the patient body.No additional information is available currently.
|
| |
|
Additional Manufacturer Narrative
|
|
The device history record (dhr) review confirms that the device met all material, assembly and performance specifications.During visual inspection, no damage was noted to the returned device.The patency test was performed, and no issue were noted.During functional testing, a good known guidewire was introduced into the transform catheter hub and the guidewire was advanced in order to seal the tip of the balloon catheter.The balloon was then inflated without any difficulty.The balloon was also deflated and no delay in balloon inflation was noted.In case of this complaint, it was reported that the transform balloon was unable to deflate inside the patient.The returned balloon was found free from any defects and it was inflated and deflated without any delay.As per the event is it suspected that the balloon could not be deflated due to thrombus formation inside the balloon lumen; however, this cannot be conclusively determined.Based on the investigation results and available information, an assignable cause of procedural factors was assigned to the as reported issue 'nv - balloon difficult/unable to deflate', as the issue is associated with a product that meets stryker design and manufacture specifications and was used in according with the dfu but due to procedural and/or anatomical factors during use, the device performance was limited.An assignable cause of anticipated procedural factors was assigned to the as reported issue 'nv - patient thrombosis (treated vessel)' since the issue is due to a known physiological effect of the procedure and/or patient condition noted with the direction for use (dfu), device labeling and/or risk documentation files.
|
| |
|
Event or Problem Description
|
|
It was reported that during the procedure, the balloon catheter was unable to deflate, due to thrombus formation inside the balloon lumen.The physician was able to get rid of the thrombus by manipulating the guidewire and the balloon was able to deflate.The balloon was continued to be used; however, similar issue occurred.The balloon was removed from the patient body.No additional information is available currently.
|
| |
|