| Catalog Number |
03.825.002 |
| Medical Device Problem Codes |
Break (1069); Device-Device Incompatibility (2919)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Reporter is a synthes employee.The device was received, the investigation is in progress, no conclusion could be drawn at the time of filing this report.Without a lot number the device history records review could not be completed.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
Device report from the (b)(6) reports an event as follows: it was reported that on an unknown date on and on an unknown procedure two (2) spindle for evolution were faulty when being used.The spindle for evolution could not disconnect the trial from the inserter as the knob disconnected from the spindle itself each time.It is unknown if there were any surgical delay or adverse event to the patient.Concomitant devices: synfix evolution trial spacer (part: 03.835.263, lot: l543726, quantity: 1); synfix evolution trial implant holder (part: 03.835.100, lot: h326553, quantity: 2); synfix evolution probe implant (part: 03.835.364, lot: l479565, quantity: 1).This report is for a spindle for evolution.This is report 2 of 2 for (b)(4).
|
| |
|
Event or Problem Description
|
|
Further it was reported that the procedure was completed successfully, however, there was a five (5) minutes of surgical delay.There was no other medical intervention required.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.A product investigation was conducted.The returned spindle for evolution (03.825.002) is an instrument routinely used in the syncage evolution system.The spindle is designed to mate with the syncage evolution (03.815.001) and synfix evolution holders (03.835.100).Visual inspection: visual inspection at customer quality (cq), identified the spindle rod was received in assembled condition with the trail implant and implant holder assembly.Also, cracked weld around the entire circumference of the spindle knob was identified.The spindle knob was able to be completely threaded out because of the crack at knob and spindle shaft intersection.With poor support due to the cracked portions the device was not able to be disassembled.Furthermore, the proximal surface of the knob shows visible signs of impaction consistent with normal use.Received condition agree with the complaint condition and therefore the complaint condition was confirmed.Dimensional inspection: since the complaint condition involved a cracked weld, a relevant dimensional check could not be performed.Document specification: with the stuck condition observed at the assembly level, lot number etch of the device could not be determined and therefore dhr review including the material review was not possible.With unknown lot number current revision of the device was reviewed and no design issue were identified.Relevant spindle assembly drawings were reviewed during this investigation.Previous investigations on the broken weld complaint condition determined that the weld was not strong enough to withstand the applied impaction load from normal use.A corrective and preventative action (capa) assessment was previously performed for the complaint condition and as a result design change order (dco) updated the spindle drawing to change weld specification from lbw 0.2 to gtaw 0.45 with filler to enhance durability.No root cause could be determined.However, the associated technique guides state that controlled light malleting may be required during trial spacer insertion.Therefore, it is possible that any unintended excess forces could have caused this cracked weld followed by stuck assembly condition.Additionally, with the unknown lot number, it is possible that the device was manufactured prior to dco changes which could have also led to the less than ideal spindle weld durability leading to complaint condition.During the investigation no unidentified product design issues or manufacturing discrepancies were observed that may have contributed to the complaint condition.Also, necessary actions required to improve the durability of weld has been already addressed per dco.Therefore, based on the investigation findings, it has been determined that no further corrective and/or preventative action is proposed device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|