Model Number BEA22-90/I20-30
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Occlusion (1984); Thrombosis (2100); Claudication (2550)
Date of Event 09/30/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The devices involved in this event will not be returned for evaluation and remain implanted in the patient.If additional information is obtained at a later time that is pertinent to this event, a follow-up report will then be submitted.
 
Event or Problem Description
The patient was initially treated with the afx2 abdominal aortic aneurysm stent; it was noted that the case was semi-emergent, but the initial procedure was completed without incident.Approximately eight (8) months post initial procedure in late september, the patient complained of numbness in the inferior limb.A ct revealed that thrombosis had clogged the entire ta.The width of the ta was 11 mm and its internal diameter was much narrower, being heavily calcified around the ta.Femoral-femoral bypass was performed and the patient was discharged from the hospital safely.There have been no additional patient sequelae reported.
 
Additional Manufacturer Narrative
A clinical evaluation of the reported event could not be completed due to a lack of receipt of relevant medical records and/or imaging.Requests were made and an inadequate response was received.As such, event determination, off label conditions, related patient harms and patient disposition could not be independently assessed.The manufacturing lot review confirmed all devices met specifications prior to release.These types of events will be monitored and trended as part of the quality system.Conclusion code - remove 11.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AFX2
Common Device Name
AFX2 BIFURCATED STENT GRAFT
Manufacturer (Section D)
ENDOLOGIX
2 musick
irvine CA 92618
MDR Report Key8091598
Report Number2031527-2018-00865
Device Sequence Number1747485
Product Code MIH
UDI-Device Identifier00818009015099
UDI-Public(01)00818009015099(17)180801
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
P040002
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 10/22/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date08/01/2018
Device Model NumberBEA22-90/I20-30
Device Lot Number1725998-008
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 10/22/2018
Supplement Date Received by Manufacturer10/22/2018
Initial Report FDA Received Date11/20/2018
Supplement Report FDA Received Date01/15/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
AFX-CUFF: 1700499-001; AFX-CUFF: 1700499-001
Outcome Attributed to Adverse Event Required Intervention;
-
-