Model Number 202.884
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 11/07/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Additional patient identifier: (b)(6).Additional device product code: hrs.Device broke intra-operatively and was not fully implanted or explanted.Complainant part is not expected to be returned for manufacturer review/investigation.Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that on (b)(6) 2018, during an open reduction and internal fixation (orif) of a pilon, the head of the cortex screw snapped off under power.The resident thought, that it was due to the angle at which it was contacted on unknown plate and was over tightened.The head of the cortex screw was removed, and the remaining portion was retained in the bone.Procedure was completed successfully with no surgical delay reported.Patient outcome is stable.Concomitant device reported: 2.4/2.7mm va-lcp t-fusion plate (part#: 02.211.265, lot# unknown, quantity 1).This report is for one (1) 2.7mm cortex screw.This is report 1 of 1 for complaint (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
2.7MM CORTEX SCREW SLF-TPNG WITH T8 STARDRIVE RECESS 24MM
Common Device Name
SCREW, FIXATION, BONE
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key8106789
Report Number2939274-2018-55110
Device Sequence Number16711114
Product Code HWC
UDI-Device Identifier10886982145116
UDI-Public(01)10886982145116
Combination Product (Y/N)N
Initial Reporter StateVA
Initial Reporter CountryUS
PMA/510(K) Number
K113364
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 11/07/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number202.884
Device Catalogue Number202.884
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/07/2018
Initial Report FDA Received Date11/27/2018
Patient Sequence Number1
Patient Age44 YR
Patient Weight79
-
-