| Catalog Number |
03.815.030 |
| Medical Device Problem Code |
Device Damaged by Another Device (2915)
|
| Health Effect - Clinical Code |
No Patient Involvement (2645)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Complainant part is expected to be returned for manufacturer review/investigation, but has yet to be received.The investigation could not be completed; no conclusion could be drawn at the time of filing this report.A review of the device history records has been requested.Device was used for treatment, not diagnosis.
|
| |
|
Event or Problem Description
|
|
Device report from synthes europe reports an event in (b)(6) as follows: it was reported that during a in- house product demonstration: alif presentation in the office demonstrating the squid, while practicing putting it together the following was observed: the 03.815.030 (silver rail with green handle) would slide over the 03.815.029 evol squid assemb/disassemb tool (black three piece) however this would remove slices of the black rail and make a carving noise while sliding the inserter over it.This report is for two (2) device.This report is 2 of 2 for (b)(4).
|
| |
|
Event or Problem Description
|
|
This report is 2 of 4 for (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.The device was received, the investigation is in progress, no conclusion could be drawn at the time of filing this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H3, h4, h6: a device history record (dhr) review was conducted: part: 03.815.030, lot: 9789899, manufacturing site: hägendorf, release to warehouse date: 12.May.2016.The device history record shows this lot of (b)(4) pieces was processed through the normal manufacturing and inspection operations with no rework or nonconformities noted.This lot met all criteria at the time of release with no issues documented during the manufacturing process.Review of the device history record showed that there were no issues during the manufacture of this product which would contribute to this complaint condition.H3, h6: a product investigation was conducted.Yes, the received condition agrees with the complaint description.Yes, the complaint can be replicated with the returned device.No, a design defect or deficiency did not contribute to the complaint condition.Received condition of device: customer returned 4 parts.Evolsquid synthes quick insert+distract art.No.: 03.815.030: both returned instruments are in a sound condition and show normal signs of usage.Evolsquid assemb / disassemb tool art.No.: 03.815.029: the two ppsu tools are as the other two instruments in a sound condition.On the surfaces where the inserter and distractor instrument glides, are grinding marks visible.The returned instruments show visible traces of wear which could potentially be the cause of the observed slices on the a-d tool.According to our important information ifu (b)(4) damaged and excessively worn devices should not be used anymore.Therefore, it can be stated that the black ppsu slices would not be pushed into the wound with the cage.H11 corrected data: b4, g4: the incorrect date was inadvertently utilized in initial medwatch.The correct date is october 17, 2018.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|