Model Number 7010
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 09/04/2018
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that shaft break occurred.The 98% stenosed, 4.5x12mm target lesion was located in the moderately tortuous and moderately calcified left anterior descending artery.A 4.5x12mm quantum maverick balloon catheter was advanced for dilation.However, it was noted that the shaft was fractured near the hub.The device was not intact during removal but simply removed as a whole all together.The procedure was completed with another of the same device.No patient complications were reported and the patient's status was stable.
 
Event or Problem Description
It was reported that shaft break occurred.The 98% stenosed, 4.5x12mm target lesion was located in the moderately tortuous and moderately calcified left anterior descending artery.A 4.5x12mm quantum maverick balloon catheter was advanced for dilation.However, it was noted that the shaft was fractured near the hub.The device was not intact during removal but simply removed as a whole all together.The procedure was completed with another of the same device.No patient complications were reported and the patient's status was stable.
 
Additional Manufacturer Narrative
Device evaluated by mfr.: returned product consisted of a quantum maverick balloon catheter.The outer shaft, inner shaft, balloon and tip were visually and microscopically examined.Visual examination revealed multiple kinks along the whole device.Microscopic examination revealed that the tip is damaged.There is contrast present in the inflation lumen and the balloon is partially loosely folded.Inspection of the remainder of the device presented no other damage or irregularities.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
QUANTUM MAVERICK
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key8112272
Report Number2134265-2018-63139
Device Sequence Number1721355
Product Code LOX
UDI-Device Identifier08714729392729
UDI-Public08714729392729
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
P860019
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/30/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/23/2020
Device Model Number7010
Device Catalogue Number7010
Device Lot Number0021297576
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/03/2019
Initial Date Received by Manufacturer 11/02/2018
Supplement Date Received by Manufacturer01/11/2019
Initial Report FDA Received Date11/28/2018
Supplement Report FDA Received Date01/30/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-