MAUDE Adverse Event Report: MICRO THERAPEUTICS, INC. D/B/A EV3 NEUROVASCULAR PIPELINE FLEX; INTRACRANIAL ANEURYSM FLOW DIVERTER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MICRO THERAPEUTICS, INC. D/B/A EV3 NEUROVASCULAR PIPELINE FLEX; INTRACRANIAL ANEURYSM FLOW DIVERTER Back to Search Results
Model Number PED-375-35
Medical Device Problem Codes Positioning Problem (3009); Activation Failure (3270)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 11/15/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Medtronic received a report that, once in place, the physician attempted to open the pipeline device but it would not open and could "not be fully attached." the physician continued to release the device up until the middle of the neck but the tip still wouldn't fully open, with the entire pipeline system eventually slipping into the aneurysm sac because the pipeline tip was not fully attached.As a result the pipeline was withdrawn and replaced with another of the same model, allowing the operation to be completed as intended.The patient was undergoing surgery to treat an unruptured, saccular aneurysm with a max diameter of 29mm and a neck diameter of 19mm.Dual antiplatelet treatment was administered, and post procedure angiographic imaging showed blood stasis.It was noted that the patient's vessel tortuosity was moderate.There were no related patient symptoms.The devices were prepared as indicated per the ifu.Ancillary devices include a marksman microcatheter.
 
Additional Manufacturer Narrative
The pipeline flex within the catheter was returned for evaluation.The pipeline flex was then pushed out from the catheter lumen without difficulty.The distal and proximal dps restraints were found to be intact.The dps sleeves were found intact with no signs of damage.The distal hypotube and ptfe shrink tubing were found to be intact with no signs of elongation.The distal and proximal ends of the pipeline flex braid appeared to be fully opened and no damage.No bends were observed on the pushwire.No damages were found with the catheter, tip coil, distal marker, re-sheathing marker, re-sheathing pad or with the proximal bumper.No other anomalies were observed.Based on the analysis findings, the customer complaint could not be confirmed.The event cause could not be determined as the returned pipeline flex braid found to be fully opened and no damage.In addition, no damages were found with the returned pushwire and catheter.It's possible that the "patient tortuous anatomy" may have contributed to the reported issues.The customer reported that the devices were prepared per the ifu.In addition, the patient vessel tortuosity was moderate.There was no indication that the event was related to a potential manufacturing issue and no dhr was requested; therefore, a device history record review was not performed.Per the instructions for use: the user should "begin to deliver the device using a combination of unsheathing the pipeline flex embolization device and pushing delivery wire simultaneously.After the distal end of the pipeline flex embolization device has successfully expanded, deploy the remainder of pipeline flex embolization device by pushing the delivery wire and/or unsheathing the pipeline flex embolization device.Re-sheathing and/or manipulation of the micro catheter, by locking down the delivery wire and moving both as a system, may facilitate expansion of the pipeline flex embolization device.Do not use in patients in whom the angiography demonstrates the anatomy is not appropriate for endovascular treatment, due to conditions such as severe intracranial vessel tortuosity or stenosis.¿ all products are 100% inspected for damages and irregularities during manufacture.Medtronic, inc.(medtronic) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information in the time allotted and has provided as much information as is available to the company as of the submission date this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic or its employees caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any "defects" or has "malfunctioned".These words are included in the fda 3500a form and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.Medtronic objects to the use of these words and others like it because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PIPELINE FLEX
Common Device Name
INTRACRANIAL ANEURYSM FLOW DIVERTER
Manufacturer (Section D)
MICRO THERAPEUTICS, INC. D/B/A EV3 NEUROVASCULAR
9775 toledo way
irvine CA 92618
MDR Report Key8118324
Report Number2029214-2018-01003
Device Sequence Number243803
Product Code OUT
UDI-Device Identifier00847536015753
UDI-Public00847536015753
Combination Product (Y/N)N
Initial Reporter CountryCH
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2018
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/01/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/25/2021
Device Model NumberPED-375-35
Device Catalogue NumberPED-375-35
Device Lot NumberA636146
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/26/2018
Initial Date Received by Manufacturer 11/19/2018
Supplement Date Received by Manufacturer02/21/2019
Initial Report FDA Received Date11/29/2018
Supplement Report FDA Received Date03/01/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-