| Catalog Number |
381854 |
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
11/14/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Medical device expiration date: unknown.(b)(6).A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.Device manufacture date: unknown.
|
| |
|
Event or Problem Description
|
|
It was reported with the use of the bd insyte¿ autoguard¿ shielded iv catheter there was an issue with sterile breach.
|
| |
|
Additional Manufacturer Narrative
|
|
The following fields have been updated to additional information: medical device lot #: 6119819.Medical device expiration date: 2019-04-30.Device manufacture date: 2016-04-29.
|
| |
|
Event or Problem Description
|
|
It was reported with the use of the bd insyte autoguard shielded iv catheter there was an issue with sterile breach.
|
| |
|
Event or Problem Description
|
|
It was reported with the use of the bd insyte¿ autoguard¿ shielded iv catheter there was an issue with sterile breach with 10 devices.
|
| |
|
Additional Manufacturer Narrative
|
|
Correction: b.5.Describe event or problem: it was reported with the use of the bd insyte¿ autoguard¿ shielded iv catheter there was an issue with sterile breach with 10 devices.H.6.Investigation summary: dhr- the product was built on afa line 6 on 2may2016 for the amount of (b)(4).Packaged on pkg line 9 on 2may16.No quality notifications were initiated during production.All challenge samples, set-up and in process testing were performed and all passed per specifications.2 non-related td¿s were in place during production.Received 2 iag 16ga units from lot number 6119819, all components within were present and intact.¿1 of the units received was partially open at one end.¿1 of the units received was partially open at both ends.The product characteristics require a minimum of 1/8¿ seal width with adhesive transfer from the top web paper to the bottom web film.This characteristic was met.The key variables that affect the packaging seal are seal transfer/width and top web adhesive presence.Both of these variables were included in the investigation.Conclusion(s): supplier ¿ defective material bd supplier oliver-tolas (ot) uses a standard reinforced paper that is common to many other suppliers, but the adhesive type and application is specific to oliver-tolas.There is sufficient evidence to demonstrate the ot material or adhesive application is the root cause.Capa 48637 was opened to investigate the package seal integrity complaints and implement corrective actions.
|
| |
|