Model Number 10° TILTED DIAM36MM FOR 25MM
Medical Device Problem Codes Difficult to Insert (1316); Device Difficult to Setup or Prepare (1487); Use of Device Problem (1670)
Health Effect - Clinical Codes Failure of Implant (1924); No Information (3190)
Date of Event 11/09/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This is the initial report submitted regarding this surgical event and medical device.
 
Event or Problem Description
Dr (b)(6) put a baseplate dwd172 without any issue and added the screws.While trying to put the glenoid sphere, it was impossible to screw.After cleaning of the glenoid 4 times in a row, there was no improvement.The 4th time, when the sphere dwd180 was removed, it fell.The surgeon proposed the use of a dwd181 and faced the same issue.He tried again and while screwing, felt that the screw thread was apparently functioning correctly and at the last moment, there was a sudden jump.The surgeon concluded that the screw thread was defective.The surgery was completed with a 40 minutes delay and additional anesthesia.The 25 mm baseplate was removed and the surgeon used a 29 mm baseplate instead.
 
Additional Manufacturer Narrative
This is the final report submitted regarding this surgical event and medical device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AEQUALIS REVERSED II GLENOID SPHERE
Common Device Name
SHOULDER JOINT METAL PROSTHESIS
Manufacturer (Section D)
TORNIER S.A.S.
161 rue lavoisier
montbonnot saint-martin, 38330
FR  38330
MDR Report Key8132784
Report Number3000931034-2018-00157
Device Sequence Number10798407
Product Code KWS
UDI-Device Identifier03700386935831
UDI-Public03700386935831
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K081059
Number of Events Summarized1
Summary Report (Y/N)N
Device Explanted Year2018
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 11/09/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device No Information
Device Expiration Date09/20/2022
Device Model Number10° TILTED DIAM36MM FOR 25MM
Device Catalogue NumberDWD181
Device Lot Number6459AS
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 11/09/2018
Supplement Date Received by Manufacturer11/09/2018
Initial Report FDA Received Date12/05/2018
Supplement Report FDA Received Date05/06/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-