Catalog Number 2C8548
Medical Device Problem Code Device Contamination with Chemical or Other Material (2944)
Health Effect - Clinical Code No Patient Involvement (2645)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).Should additional relevant information become available, a supplemental report will be submitted.
 
Event or Problem Description
It was reported that there was particulate matter in the tubing of a clearlink continu-flo solution set.The reporter described the particle as black, 3 mm in length, thin, and approximately three inches from the base of the drip chamber.This was identified prior to patient use.There was no patient involvement.No additional information is available.
 
Additional Manufacturer Narrative
The device was received for evaluation.Visual inspection on the returned sample revealed the presence of a particulate matter in the fluid path of the tubing.Further laboratory analysis of the particle revealed it was burn resin which was black in color, irregular shape, opaque, hard texture and homogenous.The reported condition was verified.The cause of the condition was due to used resin in the extruder during the tubing manufacture process.The extruders are cleaned daily as part of the tubing manufacture setup process.During the tubing manufacture process the operator must verify every hour the presence of burn resin in the di set.If there is burn resin, the operator must shift the filter.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CLEARLINK CONTINU-FLO SOLUTION SET
Common Device Name
SET, ADMINISTRATION, INTRAVASCULAR
Manufacturer (Section D)
BAXTER HEALTHCARE - CARTAGO
cartago
MDR Report Key8133485
Report Number1416980-2018-07631
Device Sequence Number1556989
Product Code FPA
UDI-Device Identifier00085412071114
UDI-Public(01)00085412071114
Combination Product (Y/N)N
Initial Reporter StateSC
Initial Reporter CountryUS
PMA/510(K) Number
K961225
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 01/10/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date02/15/2023
Device Catalogue Number2C8548
Device Lot NumberR18B15087
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/20/2018
Initial Date Received by Manufacturer 11/12/2018
Supplement Date Received by Manufacturer01/09/2019
Initial Report FDA Received Date12/05/2018
Supplement Report FDA Received Date01/10/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-