(b)(4).Further information regarding event, product, or patient details has been requested.No additional information is available at this time.The events of "tingling, pain, runny nose, and nodules" are physiological complications and analysis of the device generally does not assist allergan in determining a probable cause for this event.A review of the device history record has been initiated.If any new, changed or corrected information is noted, a supplemental medwatch will be submitted.Device labeling: 4.Warnings ¿ injection site responses consist mainly of short-term inflammatory symptoms starting early after treatment and lasting = 30 days.Refer to the adverse events section for details.5.Precautions ¿ patients may experience late-onset adverse events with use of dermal fillers, including juvéderm vollure¿ xc.Refer to adverse events section for details.6.Adverse events table 1 and 2.Injection site responses by maximum severity and duration in > 5% of subjects after initial treatment.Possible treatment site responses include: firmness, swelling, tenderness to touch, lumps/bumps, redness, pain after injection, bruising, itching, and discoloration.C.Postmarket surveillance juvéderm vollure¿ xc has been marketed outside the us since 2011 as juvéderm volift® with lidocaine.The following aes were received from postmarket surveillance on the use of juvéderm vollure¿ xc outside the united states and were not observed in the clinical study; this includes reports received globally from all sources including scientific journals and voluntary reports.These aes, with a frequency of 5 events or more, are listed in order of prevalence: inflammatory reaction, skin nodule, loss/lack of correction, hematoma, allergic reaction, necrosis, infection, flu-like symptoms, paresthesia, migration of device, abscess, drainage, herpes, malaise, headache, and anxiety.In addition, 1 report of blurry vision after injection in the periorbital area, 1 report of blurry vision after injection in an unspecified area, and 1 report of stroke after injections in an unspecified area with multiple dermal fillers were reported.In many cases the symptoms resolved without any treatment.Reported treatments for these events included the use of (in alphabetical order): analgesics, anesthetics, antibiotics, anti-allergy medications, antifungal, antihistamines, anti-inflammatory medications, antiviral, arnica, aspiration, drainage, hyaluronidase, ice, massage, nitrates, oral and topical corticosteroids, and warm compress.Outcomes for these reported adverse events ranged from resolved to ongoing at the time of last contact.
|
Healthcare professional (hcp) reported that after a patient was injected with juvéderm vollure¿ xc.The patient ¿complained of tingling, pain in the cheek area on one side of the face, runny nose, and nodules at the injection site.Treatments of vitrase & massage/heat, nitropaste & asacol-topical, imdepomethol & steroid pack were initially provided.The next day hcp treated patient with hylase and doxycycline, mupirocin, and three days later again with hylase and hbot.Patient has seen em, 2 dermatologist & a wound care specialist.Symptoms ongoing.
|