| Catalog Number |
PTA5-35-80-8-6.0 |
| Medical Device Problem Code |
Material Rupture (1546)
|
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
11/29/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Occupation = non-healthcare professional.Medical devices: merit medical pressure pump; bsx mustang balloon; cook medical flexor, check-flo, introducer balkin up & over, contralateral design; cook medical amplatz wire guide.This report includes information known at this time.A follow-up report will be submitted should additional relevant information become available.
|
| |
|
Event or Problem Description
|
|
It was reported that during dilation of the iliac artery, an advance 35 lp low profile balloon catheter ruptured.A contralateral approach was used, and when the device was inflated to nine (9) bar, the balloon was reported to be "cracked." reported pre-existing conditions include iliac stenosis and lower limb arterial occlusion.Another manufacturer's balloon catheter was used to complete the procedure.It has not been reported that a section of the device remained inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.Additional information regarding event details and patient anatomy has been requested, but is not available at this time.
|
| |
|
Event or Problem Description
|
|
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
|
| |
|
Additional Manufacturer Narrative
|
|
Blank fields on this form indicate the information is unknown, unavailable, or unchanged.Investigation ¿ evaluation.A review of the manufacturing instructions, specifications, drawing, quality control, and a visual inspection of the returned device were conducted during the investigation.The visual inspection of the returned device confirmed that the balloon had biomatter present throughout the balloon material.Both marker bands were found to be present and secured.During the functional testing of the complaint device, a pinhole was revealed, not a longitudinal rupture as reported.Additionally, a document based investigation evaluation was performed.There is no evidence to suggest the product was not made to specifications.A review of the device history record showed one nonconforming event which could potentially contribute to this failure mode.This nonconformance was for failing the leak test during manufacturing.This affected unit was scrapped and not replaced prior to order completion.It should be noted there were no other reported complaints for this lot number.Furthermore, a review of the manufactures instructions and quality control procedures was conducted, and no gaps were discovered.Moreover, an ifu is provided with this device, which states ¿it is noted that the device is indicated for percutaneous transluminal angioplasty (pta) of lesions in peripheral arteries and obstructive lesions of native or synthetic arteriovenous dialysis fistulae¿ it goes on to say ¿if balloon pressure is lost and/or the balloon ruptures, deflate the balloon and sheath as a unit.Based on the information provided, the examination of the returned product, and the results of our investigation, a definitive root cause could not be traced to the device, but instead lies with the patient¿s condition as tortuous and heavy calcification were noted.We will continue our monitoring of similar complaints and have notified the appropriate personnel of this event.Measures are being conducted to address this failure mode.Per the quality engineering risk assessment no further action is required.This report is required by the fda under 21 cfr part 803.This report is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement made in it is intended to be an admission that any cook device is defective or malfunctioned; that a death or serious injury occurred; or that any cook device caused or contributed to; or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|
| |
|
Additional Manufacturer Narrative
|
|
B5: the following additional information was received on 07dec2018: the patient's anatomy was reported to be tortuous and heavily calcified.The balloon was inflated using (1:1 ratio) contrast, and ruptured longitudinally.Blood was not noted in the inflation device, and the ruptured balloon was removed through a sheath.Another manufacturer's balloon was used to complete the procedure.No part of the device remained in the patient's body, and the patient did not need additional procedures as a result of the event.This report includes information known at this time.A follow-up report will be submitted should additional relevant information become available.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|
| |
|
Event or Problem Description
|
|
Additional information received on 07dec2018.
|
| |
|