| Model Number |
N/A |
| Medical Device Problem Code |
Device Dislodged or Dislocated (2923)
|
| Health Effect - Clinical Code |
No Information (3190)
|
| Date of Event |
06/20/2016
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Concomitant medical products: avenirstem standard cemented, 5, taper 12/14, catalog #: 0106010205; lot #: 2818098, allofit it alloclassic shell for acetabulum, uncemented, 56/kk, catalog #: 00875505600; lot #: 2817991.The manufacturer did not receive x-rays, or other source documents for review.The manufacturer did not receive the device for investigation.Where lot numbers were received for the explanted devices, the device history records were reviewed and found to be conforming.A cause for this specific event cannot be ascertained from the information provided.As soon as supplemental information becomes available an updated report will be submitted.Zimmer biomet¿s reference number of this file is (b)(4).
|
| |
|
Event or Problem Description
|
|
Patient was implanted on the right side and is being monitored for dislocation.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being filled to relay additional information, which was unknown at the time of the previous medwatch.Additional and corrected information are filled in the following fields: a cause for this specific event cannot be ascertained from the information provided.As soon as supplemental information becomes available, an updated report will be submitted.Zimmer biomet¿s reference number of this file is (b)(4).
|
| |
|
Event or Problem Description
|
|
Please refer to report 0009613350-2018-01204.
|
| |
|
Event or Problem Description
|
|
Please refer to report 0009613350-2018-01204.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being filled to relay investigation result.Dhr review: the device manufacturing quality records indicate that the released components met all requirements to perform as intended.Trend analysis: a trigger considering the following event is identified: dislocation event description: the patient who has an allofit acetablum, avenir stem and a polyethylene insert has been admitted to emergency on (b)(6) 2016 due to disabling dislocation.Review of received data: some legal documentation and patient visit reports were received (in french).The legal documentation mentions that the patient had 4 times dislocation within 5 months.All these dislocations were occurred after the first revison surgery done on (b)(6) 2016.No other relevant information in the legal documentation.The patient visit reports show that on (b)(6) 2016 during a medical consultation presence of foreign body was noticed: two metal splinters seen on x-rays, which were not seen post-operatively.On (b)(6) 2016 those foreign bodies seemed to belong to the insert which had migrated; a loss of thickness of the implant (compared to x-rays from (b)(6) 2015) is also noticed / mentioned.No anomalies in the interface between bone and cup were seen.Soft tissue with these fragments was taken to analyses.It is also noted that the patient had always pain after the first revision surgery and therefore got some painkiller.This patient had the initial surgery on (b)(6) 2015.After that time the patient had 2 revision surgeries and 4 times dislocation.See below the summary: (b)(6) 2016 1st revision surgery due to ceramic insert fracture.(b)(6) : 1st dislocation is suspected which is captured under (b)(4).2nd dislocation occurred on (b)(6) 2016 and captured under (b)(4) (this complaint).3rd dislocation occurred (b)(6) 2016 and captured under (b)(4).4th dislocation occurred (b)(6) 2016 and captured under (b)(4).(b)(6) 2016 2nd revision surgery at the union clinic and captured under (b)(4).Device analysis: no product was returned to zimmer biomet for in-depth analysis.Review of product documentation: all involved devices are intended for treatment.Conclusion: the patient who has an allofit acetablum, avenir stem and a polyethylene insert has been admitted to emergency on (b)(6) 2016 due to disabling dislocation.Some legal documentation and patient related reports were received (in french).These documents show that the patient had 2 revision surgeries and 4 dislocations within 5 months.In total 6 complaints were created for this patient.This complaint is for the second dislocation.Neither x-rays nor devices or photos of the explanted implants were received; therefore the condition of the components is unknown.The investigation results did not identify a non-conformance or a complaint out of box (coob).However, based on the given information and the results of the investigation, we were not able to identify a specific root cause for this issue.The need for corrective measures is not indicated and zimmer gmbh considers this case as closed.Zimmer biomet¿s reference number of this file is (b)(4).
|
| |
|