Model Number 10604
Medical Device Problem Codes Material Deformation (2976); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 11/23/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device is a combination product.
 
Event or Problem Description
It was reported that stent damage occurred.A 2.50 x 24 synergy drug-eluting stent was selected for treatment.However, as soon as the package was opened, it was noted that the tip of the stent was coiled.The procedure was completed with another of the same device.No patient serious injury or adverse event were reported.
 
Event or Problem Description
It was reported that stent damage occurred.A 2.50 x 24 synergy drug-eluting stent was selected for treatment.However, as soon as the package was opened, it was noted that the tip of the stent was coiled.The procedure was completed with another of the same device.No patient serious injury or adverse event were reported.
 
Additional Manufacturer Narrative
Device is a combination product.Device evaluated by mfr.: synergy ii us mr 2.50 x 24 mm stent delivery system (sds) was returned for analysis.A visual examination of the stent found that the stent was damaged on the distal stent strut rows with stent struts pulled and stretched distally.The undamaged stent outer diameter was measured within maximum crimped stent profile measurement.Stent damage most likely occurred during preparation when the stent protector was removed.A separate damaged stent was received also with no sds.The balloon cones were reviewed, and no issues were noted.The balloon wings were tightly wrapped and evenly folded and were not subjected to positive pressure.A visual and microscopic examination of the bumper tip showed signs of damage.Tip damage most likely occurred during preparation.A visual and tactile examination of the hypotube found multiple kinks along several locations of the hypotube shaft.This type of damage is consistent with excessive force that could have been applied on the delivery system.A visual and tactile examination of the outer and inner lumen and mid-shaft section found no issues along the shaft polymer extrusion.No other issues were identified during the product analysis.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNERGY
Common Device Name
BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key8151190
Report Number2134265-2018-63730
Device Sequence Number16539024
Product Code NIQ
UDI-Device Identifier08714729840213
UDI-Public08714729840213
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
P150003
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/22/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/24/2020
Device Model Number10604
Device Catalogue Number10604
Device Lot Number0022322571
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/12/2019
Initial Date Received by Manufacturer 11/23/2018
Supplement Date Received by Manufacturer03/21/2019
Initial Report FDA Received Date12/11/2018
Supplement Report FDA Received Date03/22/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-