Model Number 10605
Medical Device Problem Code Material Deformation (2976)
Health Effect - Clinical Code No Patient Involvement (2645)
Date of Event 12/06/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device is a combination product.
 
Event or Problem Description
It was reported that stent damage occurred.During unpacking of a 2.75 x 28mm synergy ii drug eluting stent, it was noted that the stent was broken.The procedure was completed with another of the same device.No patient complications were reported.
 
Additional Manufacturer Narrative
Device is a combination product.Device evaluated by mfr: synergy ii us mr 2.75 x 28 mm stent delivery system was returned for analysis.A visual examination of the stent found no issues.There was no sign of damage, stretching or lifting of the stent struts.The stent showed no signs of movement and was set equidistant between the proximal and distal markerbands.The crimped stent outer diameter was measured and was within maximum crimped stent profile measurement.The balloon cones were reviewed, and no issues were noted.The balloon wings were tightly wrapped and evenly folded and were not subjected to positive pressure.A visual and microscopic examination of the bumper tip showed no signs of damage.A visual and tactile examination of the hypotube found a hypotube break at 32 mm distal from the distal end of the strain relief.Multiple kinks were also noted along several locations of the hypotube shaft.This type of damage is consistent with excessive force that could have been applied on the delivery system.A visual and tactile examination of the outer and inner lumen and mid-shaft section found no issues with the shaft polymer extrusion shaft.No other issues were identified during the product analysis.
 
Event or Problem Description
It was reported that stent damage occurred.During unpacking of a 2.75 x 28mm synergy ii drug eluting stent, it was noted that the stent was broken.The procedure was completed with another of the same device.No patient complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNERGY
Common Device Name
BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key8163240
Report Number2134265-2018-64235
Device Sequence Number2202957
Product Code NIQ
UDI-Device Identifier08714729840282
UDI-Public08714729840282
Combination Product (Y/N)N
PMA/510(K) Number
P150003
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 02/12/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/10/2019
Device Model Number10605
Device Catalogue Number10605
Device Lot Number0022047380
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/03/2019
Initial Date Received by Manufacturer 12/06/2018
Supplement Date Received by Manufacturer01/24/2019
Initial Report FDA Received Date12/13/2018
Supplement Report FDA Received Date02/12/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No