MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION QUANTUM MAVERICK; CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION QUANTUM MAVERICK; CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS Back to Search Results
Model Number 7005
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 11/22/2018
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that shaft break occurred.The 80% stenosed, 23mm in length target lesion was located in the lightly tortuous, calcified, and 3.5mm in diameter left circumflex artery.A 3.5mm x 8mm quantum maverick balloon catheter was advanced for dilatation.However, during withdrawal of the device, it was noted that the delivery shaft was fractured.No segment of the device remained inside the patient.The procedure was completed with another of the same device.No patient complications were reported and the patient was stable.
 
Additional Manufacturer Narrative
Device evaluated by mfr: returned product consisted of a quantum maverick balloon catheter.The outer shaft, inner shaft, balloon and tip were visually and microscopically examined.Visual examination revealed multiple kinks along the hypotube.The hypotube is separated 85.6cm from the hub.Microscopic examination revealed no additional damages.There is blood present in the inflation lumen and the balloon is still tightly folded.Inspection of the remainder of the device presented no other damage or irregularities.
 
Event or Problem Description
It was reported that shaft break occurred.The 80% stenosed, 23mm in length target lesion was located in the lightly tortuous, calcified, and 3.5mm in diameter left circumflex artery.A 3.5mm x 8mm quantum maverick balloon catheter was advanced for dilatation.However, during withdrawal of the device, it was noted that the delivery shaft was fractured.No segment of the device remained inside the patient.The procedure was completed with another of the same device.No patient complications were reported and the patient was stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
QUANTUM MAVERICK
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key8164787
Report Number2134265-2018-64171
Device Sequence Number2791828
Product Code LOX
UDI-Device Identifier08714729392583
UDI-Public08714729392583
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
P860019
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/15/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/11/2021
Device Model Number7005
Device Catalogue Number7005
Device Lot Number0021734372
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/11/2018
Initial Date Received by Manufacturer 11/23/2018
Supplement Date Received by Manufacturer12/19/2018
Initial Report FDA Received Date12/14/2018
Supplement Report FDA Received Date01/15/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age70 YR
Patient Weight55
-
-