APPLIED MEDICAL RESOURCES CW002, 5MMX42CM EPIX ES SMK EVAC ANG LHK; GEI Back to Search Results
Model Number CW002
Medical Device Problem Code Material Separation (1562)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 11/27/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The incident device is anticipated to return.A follow-up report will be provided upon completion of investigation.
 
Event or Problem Description
Procedure performed: tatme.During the case the scrub nurse noticed the small black rubber just before the l detached.This insulating part was detached from its base; however it could be fixed by pushing it toward the shaft with two fingers.This issue didn't affect the evacuation performance or the monopolar features.The surgeon didn't even notice that.The cleaning method was with a wet gauze; no excessive pressure was notice during that procedure, although in the first part of the procedure the hook was cleaned more frequently.Indeed during the mucosa incision the more eschar was noticed than in the mesorectal dissection.Settings of the monopolar, 60 cut.The green sheath has been always put over the l tip to protect during the insertion or extraction from the trocar.Also i noticed the tip was bent and the green sheath couldn't cover the tip till the end, so the nurse pushed it back in place and it worked well.I asked for the sample, but when they went to put in a plastic bag, i saw they put in a decontaminating pool, then it "has been" washed.Not sure if this "affect" the engineering test.Patient status: no patient injury.Type of intervention: unknown.
 
Event or Problem Description
Procedure performed: tatme.During the case the scrub nurse noticed the small black rubber just before the l detached (see the picture).This insulating part was detached from its base, however it could be fixed by pushing it toward the shaft with two fingers.This issue didn't affect the evacuation performance or the monopolar features.The surgeon didn't even notice that.The cleaning method was with a wet gauze, no excessive pressure was notice during that procedure, although in the first part of the procedure the hook was cleaned more frequently.Indeed during the mucosa incision the more eschar was noticed than in the mesorectal dissection.Settings of the monopolar, 60 cut.The green sheath has been always put over the l tip to protect during the insertion or extraction from the trocar.Also i noticed the tip was bent and the green sheath couldn't cover the tip till the end, so the nurse pushed it back in place and it worked well.I asked for the sample, but when they went to put in a plastic bag, i saw they put in a decontaminating pool, then it has been washed.Not sure if this affect the engineering test.Patient status: no patient injury.Type of intervention: unknown.
 
Additional Manufacturer Narrative
The event unit was returned to applied medical for evaluation.Visual inspection confirmed the tip insulation had detached from the shaft.Based on the condition of the returned unit, the reported event was caused by a modification to the tip of the device.The probability and criticality of harm resulting from this failure have been evaluated and were found to be at an acceptable level.Applied medical continuously seeks to improve the form, function and ease of use of its products.As part of this process, applied medical is currently researching possible product enhancements intended to further minimize the potential for this type of event to occur.Recall number: 2027111-12/06/18-001-r.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CW002, 5MMX42CM EPIX ES SMK EVAC ANG LHK
Common Device Name
GEI
Manufacturer (Section D)
APPLIED MEDICAL RESOURCES
22872 avenida empresa
rancho santa margarita CA 92688
MDR Report Key8172070
Report Number2027111-2018-00469
Device Sequence Number11082617
Product Code GEI
UDI-Device Identifier00607915136147
UDI-Public(01)00607915136147(17)210912(30)01(10)1336418
Combination Product (Y/N)N
Initial Reporter CountryIT
PMA/510(K) Number
K171684
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Remedial Action Recall
Type of Report Initial,Followup
Report Date (Section B) 02/14/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/12/2021
Device Model NumberCW002
Device Catalogue Number101470783
Device Lot Number1336418
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/11/2018
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 11/27/2018
Supplement Date Received by Manufacturer11/27/2018
Initial Report FDA Received Date12/17/2018
Supplement Report FDA Received Date02/14/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-