Catalog Number PLL161407
Medical Device Problem Code Migration (4003)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 11/21/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Corrected data - (b)(4).
 
Event or Problem Description
On (b)(6) 2018, this patient underwent an office based endovascular repair of an abdominal aortic aneurysm using gore® excluder® aaa endoprosthesis.During the placement of one of the iliac extender components in the common iliac artery, the device inadvertently migrated proximally.The patient was then transferred to the hospital and during the attempted relining of the aorta and left common iliac the proximal iliac extender component was deployed above the level of the renal arteries, superior mesenteric artery and celiac artery.The decision to open the patient and explant the devices was made.All three components were removed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AORTIC EXCLUDER AAA ENDOPROSTHESIS (LOW PROFILE)
Common Device Name
SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
Manufacturer (Section D)
W.L. GORE & ASSOCIATES
flagstaff AZ
MDR Report Key8174024
Report Number3013164176-2018-00123
Device Sequence Number1407132
Product Code MIH
UDI-Device Identifier00733132618767
UDI-Public00733132618767
Combination Product (Y/N)N
Initial Reporter StateCT
Initial Reporter CountryUS
PMA/510(K) Number
P020004
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2018
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/21/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date07/15/2021
Device Catalogue NumberPLL161407
Device Lot Number18361863
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date12/18/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age86 YR