| Model Number |
N/A |
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
11/19/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The device has not been returned, at this time, to the manufacturer for evaluation.A lot history review (lhr) of recv0748 showed no other similar product complaint(s) from this lot number.
|
| |
|
Event or Problem Description
|
|
It was reported that a powerglide pro midline catheter 20 ga wire broke off in patient.It was stated patient was unharmed and all parts were removed.
|
| |
|
Additional Manufacturer Narrative
|
|
The information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, trend analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of an uncoiled guidewire was confirmed and the cause appeared to be use-related.The product returned for evaluation was one 20ga x 10cm powerglide pro midline catheter assembly.The safety mechanism was engaged over the needle tip and the catheter was detached from the assembly.Usage residues were observed throughout the sample.The guidewire exhibited breaks in both the inner core and outer coil wires 3.5cm from the distal tip.The coil wire was not elongated.Microscopic inspection of the guidewire revealed curved shape memory in the vicinity of the breaks.The fracture surfaces were granular and the core wire fracture surface exhibited a region of increased luster.Inspection of the needle bevel revealed mechanical damage along the proximal edge.The break characteristics and needle damage were consistent with damage initiated by retraction of the wire against the needle bevel, followed by tensile (pulling) stress.The guidewire should not be retracted following advancement but should instead be withdrawn with the needle as a unit.A lot history review (lhr) of recv0748 showed no other similar product complaint(s) from this lot number.
|
| |
|
Event or Problem Description
|
|
It was reported that a powerglide pro midline catheter 20 ga wire broke off in patient.It was stated patient was unharmed and all parts were removed.
|
| |
|
Additional Manufacturer Narrative
|
|
Labeled for single use - correction.The following were reviewed as part of this investigation: patient severity, trend analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of an uncoiled guidewire was confirmed and the cause appeared to be use-related.The product returned for evaluation was one 20ga x 10cm powerglide pro midline catheter assembly.The safety mechanism was engaged over the needle tip and the catheter was detached from the assembly.Usage residues were observed throughout the sample.The guidewire exhibited breaks in both the inner core and outer coil wires 3.5cm from the distal tip.The coil wire was not elongated.Microscopic inspection of the guidewire revealed curved shape memory in the vicinity of the breaks.The fracture surfaces were granular and the core wire fracture surface exhibited a region of increased luster.Inspection of the needle bevel revealed mechanical damage along the proximal edge.The break characteristics and needle damage were consistent with damage initiated by retraction of the wire against the needle bevel, followed by tensile (pulling) stress.The guidewire should not be retracted following advancement but should instead be withdrawn with the needle as a unit.A lot history review (lhr) of recv0748 showed no other similar product complaint(s) from this lot number.
|
| |
|
Event or Problem Description
|
|
It was reported that a powerglide pro midline catheter 20 ga wire broke off in patient.It was stated patient was unharmed and all parts were removed.
|
| |
|